R E M E D Y I N G F A U L T S
Compressor overheated
Cause of fault
Remedy
Inlet filter cartridge contaminated
Replace
Ambient temperature too high
Improve room ventilation /
Cooling air inlet and outlet insufficient
Observe minimum distances (see Installation
Instructions)
Air intake hose too long
Reduce length of the air intake hose
Air intake hose diameter too small
Use a larger diameter
Wrong compressor rotation direction
Ensure correct phase rotation,
observe rotation direction arrow!
Inlet and outlet valves contaminated / defective Clean, replace if necessary
Safety valve leaks
Cause of fault
Remedy
Inlet and outlet valves of the following pressure
stage defective
Clean, replace if necessary
Sinter filter of the following water separator
blocked
Replace
Safety valve leaky
Replace
Oil taste in the air
Cause of fault
Remedy
Mole carbon filter cartridge saturated
Replace
Compressor oil unsuitable
Use prescribed oil quality
Filter cartridge unsuitable
Use prescribed filter type
Cylinder(s), piston(s) or piston ring(s) defective
Replace