LW 300 E / LW 450 E
Page A - 47
A
M A I N T E N A N C E A N D S E R V I C E
Oil sieve change
Oil sieve change as follows:
• Loosen cover screws (4 pcs).
• Remove the cover, the cover gasket and the oil sieve.
• Clean the oil sieve with petroleum-ether or replace the defective oil sieve.
• Replace the gaskets.
• Soak the gaskets with oil before placing (respect mounting direction).
• Be sure to position the arrow (see Fig., Pos. 1) from the new oil sieve opposite to inlet and return
ports of the pump (see Fig., Pos. 2).
• Remount the cover with the 4 cover screws. Tightening torque: 4.5 - 8 N.
The oil sieve change is now completed.
Maintenance intervals
• We recommend cleaning or replacing the oil sieve every 1,000 working hours.
1.
Correct oil sieve mounting direction
2.
Version: 261012-001 E