Replace inlet and outlet valves 1st and 2nd stage
Change inlet and outlet valves 1st and 2nd stage as follows:
Remove Inlet / Outlet Valve
• Loosen pipe connections
• Loosen valve head screws (Fig. 1)
• Remove valve head
• Pull out inlet and outlet valve (Fig. 2). CAUTION: Observe that
the lower copper valve ring is also pulled out. (It can still stick
inside the cylinder)
• Check valve head if defective
Install Inlet / Outlet Valve - see following page
Fig. 1 - Loosen valve head screws
Fig. 2 - Pull out inlet and outlet valve
Note
The figures of the parts can differ due to the different stages.
i