5-6
F-459-R1
DREXEL SLT30/35 AC CALIBRATION PROGRAMMING
Traction Setup
Traction Setup - This submenu contains all the adjustable
parameters that are available in the traction controller.
Parameter
Units
Min
Max
Default
Description
Throttle High
%
0
1000
15
Sets the throttle high
value when calibrating
the throttle pot
Throttle Low
%
0
1000
925
Sets the throttle low
value when calibrating
the throttle pot
Brake Pot High
%
0
1000
200
Sets the brake pot high
value when calibrating
the brake pot
Brake Pot Low
%
0
1000
700
Sets the brake pot low
value when calibrating
the brake pot
M1 Acceleration
%
0
1000
65
Sets the maximum
acceleration
percentage for mode 1
M1 Neutral Braking
%
0
100
20
Sets the maximum
regenerative braking
percentage for mode 1
M1 Max Speed
%
0
100
100
Sets the maximum
truck speed percentage
for mode 1
M2 Acceleration
%
0
100
65
Sets the maximum
acceleration
percentage for mode 1
M2 Neutral Braking
%
0
100
20
Sets the maximum
regenerative braking
percentage for mode 1
M2 Max Speed
%
0
100
100
Sets the maximum
truck speed percentage
for mode 1
M3 Acceleration
%
0
100
65
Sets the maximum
acceleration
percentage for mode 1
M3 Neutral Braking
%
0
100
20
Sets the maximum
regenerative braking
percentage for mode 1
M3 Max Speed
%
0
100
100
Sets the maximum
truck speed pecentage
for mode 1
STORE CHANGES
Sets to 1 to store
changes made to any
Traction Setup
parameters
https://www.forkliftpdfmanuals.com/