ASSEMBLING YOUR L&L EASY-FIRE KILN
easy-fire-install.pdf
3/1/2007 Rev 1.3
Page 1
2007
L&L Kiln Mfg, Inc. 505 Sharptown Rd, Swedesboro NJ 08085 P:856.294.0077 F:856.294.0070 [email protected] hotkilns.com
3) Push the Element Cover Box up against the kiln
and position it over the screws through the large part
of the tear-drop holes . Tighten the screws .
4) Attach all the wires to their proper place on the
terminal boards .
5) Close the Control box and screw in the two screws
that hold it in place at the top of the Element Cover
Box .
If you removed the panel separate from the
element cover box
1) Take the element terminal box and place it on the
screws on the
left
hand side of the element connection
terminals (facing from the front) .
2) Gently push the right side of the element cover
box open enough to allow access to feed the element
and thermocouple connection wires through the same
holes that you previously removed them from .
3) Take the 3 screws that you removed from the right
side of the element cover box and replace and tighten
them .
Below:
4) Next tighten the 3 screws on the left hand side of
the element cover box .
5) Reconnect the wires to the appropriate numbered
terminals .
6) You are now ready to reattach the hinge portion of
the dynatrol panel .
ASSEMBLING YOUR L&L EASY-FIRE KILN