Page 22 of 69
Issue: 1.8
Installation and Binding of External Devices
© Gyr
E470 Tokenless Smart Prepayment Meter
Installer Fits
Meter
Installer enters 6 digit default
commissioning code
Meter enters installation
mode
Installer enters MPAN/Cust #
Code entered using two
push buttons
Any remaining credit entered
from previous meter
Arrears entered from
previous meter
Meter fitter enters personal
authorisation code
Meter sends to system:
MPAN
Meter serial #
Payment card # Credit value set
Arrears value set Register readings
Removal code
Exchange Code
System sends Meter:
Configuration Update
(Previous meter setting s
if an exchange meter)
Installation complete
Code entered using two
push buttons
Code entered using two
push buttons
Code entered using two
push buttons
Meter generates random 6
digit numbers for meter
removal and meter exchange
The meter will recognise and accept a default service code to allow the
installer to enter the installation process. The default service code will be 6
digits in length and programmed during factory configuration. NOTE: it is
expected the service code will be valid across all meters. Following
completion of the commissioning process the Default service code
operation will be disabled.
On acceptance of service code the meter will enter the installation process.
The first parameter for entry will be the customer MPAN or customer
number. See Display section.
The MPAN or customer number length will be configurable up to allow up to
16 digits to be entered.
NOTE