Commands and meter data
Issue: 1.8
Page 27 of 69
E470 Tokenless Smart Prepayment Meter
© Gyr
Clear credit transaction log.
Option to open/close meters contactor. (shows OFF display
second CoT/S command to close contactor).
Option to Zero PPU tariff plan.
Option to reset Billing Period.
Zero Standing Charges.
Zero total credit.
Zero total payments.
Option to clear any future tariffs.
Clear Profile data log.
The CoT/S command will trigger a Snapshot of readings. The returned data
includes data required for prepayment or credit operation and consists of:
Data Item
Returned in1 Details
Date and Time stamp
H
Electricity Meter Status flags
H
See2 below
Message ID
P
Message ID = COTS
MPAN/Customer #
P
Meter Serial Number
P
Credit Mode
P
Denotes credit or prepayment operating mode
Emergency credit flags
P
Denotes emergency credit taken or not
Present Balance Register
P
Arrears Register
P
Rate 1 kWh register
P
Rate 2 kWh register
P
1 Returned In’ column denotes whether the item is returned in the message
header (H) or as part of the message payload.
2 Meter status information includes flags to indicate fault conditions/status
of the electricity meter.
Flags will indicate the following:
Watchdog Error
Reverse energy detected
Real Time Clock Error
SIM card flap tamper
FRAM (memory) error
SIM carriage detected
Program download active
Fingerprint stats error
Meter in Emergency mode
Fingerprint other error