![background image](http://html1.mh-extra.com/html/lancer/escort-iii/escort-iii_installation-and-service-manual_3478733017.webp)
6.12 ELECTRONIC ICE BANK CONTROL
WARNING
DISCONNECT FROM POWER SOURCE BEFORE BEGINNING THIS PROCEDURE.
A. Remove two screws retaining Rear Lid over Agitator Deck and remove Lid.
B. Remove cover from electronic ice bank control.
C. Disconnect ice bank probe lead from control board.
D. Remove three leads from ice bank control,
noting which lead goes to the Junction Box (HOT IN)
and which lead goes to the Compressor (HOT OUT)
. The third lead goes to Agitator Motor. The
lead going to the Compressor is on Pin 1 of the Agitator/IBC connector and the lead going to
the Junction Box is on Pin 3 (see Wiring Diagram, Section 9.1, Page 22).
E. Remove the screws holding the ice bank control bracket to the Agitator deck and remove the
control. Save screws for reinstallation.
F.
Remove one screw holding the bracket on the replacement electronic ice bank control housing
and loosen the other. Spin the bracket 90°, reinstall screw, and tighten both screws.
G. Mount new control to the Agitator Deck, using the screws removed in Step E.
H. Remove the cover of the replacement control. Connect lead from Compressor to screw
terminal marked "HOT OUT". Connect lead from Junction Box and Agitator Motor to terminal
marked "HOT IN" (see Wiring Diagram, Section 9.1, Page 22).
I.
Plug the Probe Lead into the connector on the PCB.
J.
Check all connections, and install Control Housing Assembly Cover. Tie all leads together,
ensuring that all leads are clear of any rotating equipment.
K. Reconnect to power source. When power is supplied to the EIBC, there is a five minute delay
before Compressor start-up. The Power Indicator Lamp should be illuminated and visible
through the Control Housing Assembly Cover. When the Compressor starts, the Power
Indicator Lamp will turn off.
L.
Replace Rear Lid over Agitator Deck and the two screws.
M. Conduct operational check of unit.
6.13 AGITATOR MOTOR
WARNING
DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET.
A. Remove lid over agitator deck.
B. Unplug wiring harness from agitator deck.
C. Remove four (4) screws holding agitator motor bracket to agitator deck.
D. Disconnect agitator motor from wiring harness and remove.
E. Inspect propeller to be sure no blades are broken. Remove and replace propeller if damaged.
F.
Replace agitator motor and propeller by reversing above procedure.
6.14 AGITATOR DECK
WARNING
DISCONNECT FROM POWER SOURCE BEFORE BEGINNING THIS PROCEDURE. WATER
BATH MUST BE DRAINED AND ICE BANK MUST BE COMPLETELY MELTED.
A. Remove two screws retaining Rear Lid over Agitator Deck and remove Lid.
B. Remove cover from electronic ice bank control.
C. Disconnect ice bank probe lead from control board.
D. Disconnect wire harness from Agitator Deck.
E. Remove foam plug from hole around ice bank probe lead.
F.
Remove two (2) nuts holding Agitator Deck to tank assembly.
G. Lift Agitator Deck out of unit.
H. Installation is reverse of removal.
6.15 WATER COIL CAGE ASSEMBLY
WARNING
DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET.
A. Close inlet water shut off valve.
14
dinecompany.com