DISPENSER INSTALLATION HIGHLIGHTS

This unit has been factory sanitized per Lancer specifications.

Listed below are six critical elements which will aid in a successful installation.
1.   Fill water bath until water overflows from tank overflow tube.

2.   The carbonator pump motor must be disconnected from the power supply (see Section 1.7) prior to connection to 

water supply for initial build up of ice bank. Failure to do so will result in automatic shut off of carbonator (see item 

6 below) or damage to the pump.

3.   If this dispenser is installed in an area that is susceptible to ±10% variation of the nominal line voltage, consider  

installing a surge protector or similar protection device.

4.   There is a five (5) minute delay which prevents the compressor and condenser fan from starting until the delay 

has lapsed. If electrical current is interrupted, there is always a five (5) minute delay before the compressor starts.

5.   Supply Water Pressure: Minimum - 25 PSI (0.172 MPA); Maximum - 50 PSI (0.345 MPA);  If pressure is over 50 

PSIG (0.345 MPA), a water pressure regulator must be used.

6.   On units with the built in water regulator, the regulator must be removed if inlet water pressure is less than 25 

PSIG. 

(0.172 MPA)

PUNTOS IMPORTANTES EN LA UNIDAD DISPENSADORA 

Esta unidad ha sido saneada en fabrica por las especificaciones de Lancer.

A continuacion se relacionan 6 puntos importantes para una connecta instalacion.
1.   Llene  el  bano-Maria  hasta  que  el  agua  se  desborde  sobre  el  tubo  que  controla  la  derrama  del  tanque.

2.   El motor de la bomba del carbonatador debe desconectarse electricamente (Ver Manual - Seccion 1.7) antes 

de conectar el suministro de agua para la formacion inicial del banco de hielo. De no hacerse esto resultaria en 

un bloqueo automatico del carbonatador (ver abajo el punto 6) o en danos a la bomba.

3.   Si la unidad va a ser instalada en un area en la que puedan darse variaciones de voltage de + 6 - 10% de su 

valor nominal, se debe considerar la conveniencia de instalar un estabilizador de corriente o sistema de 

proteccion similar.

4.   Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado 

ese tiempo. Si hay algun corte en la corriente electrica siempre se producira esa demora de 5 minutos antes de 

arrancar el compresor.

5.   Presión de suministro del agua de red: Minimo 25 PSI (0.172 MPA); Maximo 50 PSI (0.345 MPA). En unidades 

sin regulador de presión incorporado, si la presión del agua es superior a 50 PSIG (0.345 MPA) se debe usar un 

regulador de presión.

6.   En unidades con regulador de presión incorporado, el regulador debe der eliminado cuando la presión de entrada 

de agua sea inferior a 25 PSIG (0.172 MPA).

REGLES DE SECURITE POUR L’NSTALLATION DU DISTRIBUTEUR DE SODAS 

La proprètè da cet ensamable est assurè à I’usine sulvant les spècifications èmis par Lancer .

Il est essentiel de respecter les 6 points suivants pour l’installation de l’appareil:
1.   Remplir le bain-Maire jusqu’a ce que l’eau dèborde par le tuyau de trop-plein du rèservoir.

2.   Le moteur de la pompe du carbonateur doit etre dèbranchè de l’alimentation èlectrique (Voir le manuel, 

Section 1.7) avant l’arrivèe de l’eau pour la formation initiale de la glace. Oublier ou nègliger cette opèration 

provoquera l’arret automatique du carbonateur (voir le point 6 cidessous) ou causera des dommages à la pompe.

3.   Si le distributeur es installè dans une zone ou la tension èlectrique nominale est susceptible de variations de (+) 

10%, il est conseillè d’installer un appaeil de protection contre les sautes de courant.

4.   Un d’lai de 5 minutes empeche le compresseur et la ventilation du condesateur de se mettre en marche avant 

que ce lees de temps ne se soit ècoulè. Lorsque le courant èlectrique es interrompu, il y a toujours un dèlai de 5 

minutes avant que le presseur ne se mette en.

5.   Pression de l’eau: Minimum 25 PSI (0.172 MPA); Maximo 50 PSI (0.345 MPA). Sur les unitès qui n’ont pas de 

règulateur de pression d’eau incorprè, si la pression d’H2O est supèrieure à 50 PSIG (0.345 MPA), un règulateur 

de pression d’eau doit etre utilsisè.

6.   Sur les unitès avec règulateur d’eau incorporè, le règulateur doit etre enlevè si la pression d’arrivve est inferièure 

à 25 PSIG (0.172 MPA)

!

!

!

!

!

!

Summary of Contents for 605

Page 1: ...rt Warranty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0732 03 OCTOBER 20 2009 FOR QUALIFIED INSTALLER ONLY Model 605 Cold Carbonated Dispenser Operation Manual PN 28 0732 03 Lan...

Page 2: ...SELECTING A COUNER LOCATION 10 1 4 MOUNTING THE DISPENSER 10 1 5 CONNECTING THE DRAIN 11 1 6 FILLING UNIT WITH WATER 11 1 7 CONNECTING TO ELECTRICAL POWER 11 1 8 CONNECTING TO WATER SUPPLY 12 1 9 CONN...

Page 3: ...26 5 1 COMPRESSOR DECK ASSEMBLY 26 27 5 2 MINIPUMP ASSEMBLY FIVE FLAVOR PN 82 3900 28 29 5 3 FOAM TANK CABINET ASSEMBLY 30 31 5 4 CARBONATOR WATER SYRUP LINE ASSEMBLIES 32 33 5 5 CONTROL HOUSING ASSE...

Page 4: ...03 2 mm ELECTRICAL 230VAC 50Hz 3 5AMPs WEIGHT Empty 125 lbs 56 8 kg Operating 163 lbs 74 1 kg Shipping 140 lbs 63 6 kg ICE Bank Weight 11 13 lbs 5 5 9 kg FITTINGS Soda Inlets 3 8 barb Brand syrup inle...

Page 5: ...Clamps Fittings Water Booster Water Regulator Precision Cutters if removing replacing carbonator tank CONSIDER LOCATION OF THE FOLLOWING PRIOR TO INSTALL Water supply lines Drain Is the countertop lev...

Page 6: ...in supervisi n Esta unidad no ha sido dise ada para suministrar productos l cteos La temperatura ambiente operativa m nima m xima para el dispensador es de 40 F a 90 F 4 C a 32 C No opere la unidad po...

Page 7: ...izador de corriente o sistema de proteccion similar 4 Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado ese tiempo Si hay algun corte en la cor...

Page 8: ...iques locaux lorsque vous faites des connexions Chaque distributrice doit avoir un circuit lectrique s par N utilisez pas de cordons prolongateurs avec cet appareil Ne pas le brancher avec d autres ap...

Page 9: ...nd local standards It is the responsibility of the installer to ensure compliance Proporcione un suministro adecuado de agua potable La l nea de suministro de agua debe ser de una tuber a de por lo me...

Page 10: ...the counter in accordance with NSF directives B When permanently bolting the dispenser to the countertop seal the dispenser base to countertop with a bead of clear FDA approved silicone caulk or seala...

Page 11: ...RRA DE TRES AGUJEROS USE UN M TODO APROBADO PARA PONER A TIERRA LA UNIDAD AL HACER LAS CONEXIONES RESPETE TODOS LOS C DIGOS EL CTRICOS LOCALES CADA DISPENSADOR DEBE TENER UN CIRCUITO EL CTRICO INDEPEN...

Page 12: ...mount regulator using a flare seal washer PN 05 0011 Use a back up wrench to prevent damage to the regulator assembly D Route the gas line through a hole in the counter or through the opening in the r...

Page 13: ...location for example under the counter and secure the CO2 cylinder with a safety chain C Using tubing and fittings from the installation kit connect the tubing assembly to the tank mount regulator usi...

Page 14: ...EAR VIEW Figure 1 Setting 3 Way Adjustable Back Blocks will be restricted D Remove valve cover from valve 3 E Connect the 1 4 fast on from the water booster harness to the black side terminal on the v...

Page 15: ...O ANILLO NO EST ROTO O DA ADO SI EST DA ADO REEMPL CELO O ANILLO ATTENTION PR CAUTION POUR ASSURER O RING N EST PAS D CHIR OU ENDOMMAG REMPLACEZ LA SI O RING 1 Check o ring on back block Replace o rin...

Page 16: ...TION Prepare sanitizing solutions in accordance with the manufacturer s writ ten recommendations and safety guidelines The solution must provide 100 parts per million PPM chlorine e g Sodium Hypochlor...

Page 17: ...er and replace cover K Draw drinks to flush residual sanitizing solution Taste the beverage to verify that there is no off taste If an off taste is found additional flushing may be required 3 6 CLEANI...

Page 18: ...3 MPA for BIB pumps B Open shutoff fully C Remove syrup flow control form upper body and clean out any foreign material to ensure smooth free spool movement 4 4 No product dispensed A Water and syrup...

Page 19: ...t shut off A Cup lever may be sticking or binding B Switch not actuating freely C Solenoid armature not returning to bottom position A Correct or replace lever B Check switch fro free actuation C Repl...

Page 20: ...and will not cut off First check that the three minute carbonator timer has not timed out Turn unit OFF then ON If the pump shuts off in less than 30 seconds the dispenser is not frozen A PCB malfunct...

Page 21: ...e PCB assembly G Refer to wiring diagram and correct H Replace ice bank probe I Reset circuit breaker on top of control box If breaker trips again see Section 8 22 J Connect ice bank probe to PCB 4 14...

Page 22: ...enser fan motor F Repair and recharge G Replace compressor 4 18 Compressor runs normally but water line is frozen A Low water level in water bath B Syrup in water bath C Water cage is out of position...

Page 23: ...pened A Out of CO2 CO2 not turned on or low CO2 pressure B Out of syrup C BIB connector not tight D Kinks in syrup or gas lines A Replace CO2 supply turn on CO2 supply or adjust CO2 pressure to 70 80...

Page 24: ...A Timed out B Fuse blown on PCB C Faulty carbonator probe D Air in carbonator E Faulty PCB A Check water supply turn machine off and on B Replace fuse F1 on PCB C Disconnect J14 connector from PCB If...

Page 25: ...25 NOTES...

Page 26: ...5 ILLUSTRATIONS PARTS LISTINGS AND WIRING DIAGRAMS 5 1 COMPRESSOR DECK ASSEMBLY 27 15 32 18 16 7 5 20 26 2 1 31 25 3 4 6 14 19 17 33 13 22 21 24 8 12 23 11 10 29 28 30 9 26...

Page 27: ...on Red 1 17 47 0344 Process Tube Dryer Red 1 18 47 1655 Tube High Side Red 1 19 47 1656 Tube Condenser Out Red 1 20 51 0061 Accumulator 0 375 Holes 21 30 6844 Retainer Baffle Condenser Red 1 22 50 032...

Page 28: ...28 5 2 MINIPUMP ASSEMBLY FIVE FLAVOR PN 82 3900 2 4 11 5 6 8 7 9 10 1 3...

Page 29: ...0504 Screw 8 18 x 0 375 3 04 0275 Screw 8 16 x 0 427 4 05 1687 Body Cap Housing Dampener 5 01 1483 Elbow Assy Syrup 1 4 Barb 6 02 0089 O Ring 2 012 97 0999 7 04 0359 Screw 8 32 x 3 100 PHD PH 8 54 009...

Page 30: ...30 5 3 FOAM TANK CABINET ASSEMBLY 10 7 8 5 6 18 19 12 13 17 14 15 16 2 11 9 3 4 1...

Page 31: ...y Red 1 7 05 2593 01 Drip Tray No Drain Red 1 8 23 1462 Cup Rest Wire Red 1 9 30 9864 Plate Faucet Red 1 10 30 9863 Plate Splash Red 1 11 12 0097 Switch Key Lock Maintain Spade 12 30 15022 Bracket Pum...

Page 32: ...32 5 4 CARBONATOR WATER SYRUP LINE ASSEMBLIES 3 13 12 11 1 10 4 5 6 7 8 9 9 2...

Page 33: ...Syrup 3 Red 1 7 48 2512 Tube Assy Syrup 4 Red 1 8 48 2513 Tube Assy Syrup 5 Red 1 9 02 0005 O Ring 10 23 1457 Cage Assy Water Red 1 11 17 0341 Check Valve Assy 3 8 01 0669 Body Check Valve 01 0689 Sl...

Page 34: ...mpressor 11 52 0907 Lead Assy Compressor 12 52 1210 Harness Assy Recirc Delta 13 52 0908 Harness Assy Carb Delta II 14 11 0186 Jumper Terminal 4 Circuit 15 11 0008 Tie Wire 16 52 0868 01 Lead Assy Kil...

Page 35: ...prevent possible harm to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulatio...

Page 36: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: