15
1.17 ADJUSTING WATER TO SYRUP (RATIO) BRIX (LEV
®
)
A. Hold the Lancer brix cup under the syrup separator and activate valve. Check brix.
B. To obtain the proper brix, use screwdriver to adjust syrup flow control (see Figure 2).
C. Once proper ratio is obtained repeat to verify.
D. Remove syrup separator (PN 54-0031 installed in Section 1.16.F above).
E. Install diffuser and nozzle.
F. Slide down ID panel.
G. Repeat process for each valve.
1.18 VALVE ACCESS (SYRUP MODULE OR SODA MODULE)
A. Removal from Back Block
1. Raise valve shroud and lock in place.
2. Turn back block shut-off to the closed position (counterclockwise rotation).
3. Lower shroud and activate the valve pushbutton to relieve pressure.
4. Raise valve shroud and lock in place again.
5. Unplug valve harness from PCB.
6. Raise valve retainer.
NOTE:
The retainer cannot be pulled up until the back block shut-off is properly closed.
7. Pull the valve off of the back block.
B. Mounting on Back Block
!
CAUTION
USE CARE TO INSURE O-RING IS NOT TORN OR OTHERWISE DAMAGED. IF DAMAGED, REPLACE
O-RING.
PRECAUCIÓN
TENGA CUIDADO PARA ASEGURAR O-ANILLO NO ESTÁ ROTO O DAÑADO. SI ESTÁ DAÑADO
REEMPLÁCELO O-ANILLO.
ATTENTION
PRÉCAUTION POUR ASSURER O-RING N’EST PAS DÉCHIRÉ OU ENDOMMAGÉ. REMPLACEZ-LA SI
O-RING.
1. Check o-ring on back block. Replace o-ring, if necessary.
2. Apply 111 Lubricant (or another NSF approved lubricant) to o-ring, if necessary.
3. Press valve into the back block.
4. Lower the valve retainer to lock the valve in place.
5. Turn the back block shut-off to the open position (clockwise rotation).
6. Connect the valve harness to the proper position on the PCB.
7. Lower valve shroud.
2. SCHEDULED MAINTENANCE
2.1 DAILY
A. Remove the cup rest and wash in warm soapy water.
B. Pour warm soapy water into the drip tray and wipe with a clean cloth.
C. Using a clean cloth and warm soapy water, wipe off all exterior surfaces of the unit and nozzles.
D. Replace the cup rest.
2.2 WEEKLY
A. Remove the unit’s top cover and check the level of water in the water bath. Replenish as
required, and replace the top cover.
2.3 MONTHLY
A. Unplug the dispenser from power source.
B. Remove the top cover, and clean the dirt from the unit’s condenser using a soft brush.
C. Replace the top cover and plug the unit into the power source.
2.4 EVERY SIX MONTHS
A. Clean and sanitize the unit using the appropriate procedures outlined in Section 3.
Summary of Contents for 605
Page 25: ...25 NOTES...
Page 28: ...28 5 2 MINIPUMP ASSEMBLY FIVE FLAVOR PN 82 3900 2 4 11 5 6 8 7 9 10 1 3...
Page 30: ...30 5 3 FOAM TANK CABINET ASSEMBLY 10 7 8 5 6 18 19 12 13 17 14 15 16 2 11 9 3 4 1...
Page 32: ...32 5 4 CARBONATOR WATER SYRUP LINE ASSEMBLIES 3 13 12 11 1 10 4 5 6 7 8 9 9 2...