_ 18
User manual LAM1006 / LAM1007
Regulating the minimum
fl
ame
After lighting the burners, turn the control knob
to the minimum setting then remove the knob
(this can easily be removed by applying gentle
pressure).
Using a small «terminal» type screwdriver the
regulating screw can be adjusted as in image
below. Turning the screw clockwise reduces the
gas flow, whilst turning it anticlockwise increases
the flow - use this adjustment to obtain a flame
of approximately 3 to 4mm in length and then
replace the control knob.
When the gas supply available is LPG - the screw
to set the idle flame must be turned clockwise to
the end stop.
When you have carried out the new gas regulation,
replace the old gas rating plate on your appliance
with one (supplied with hob) suitable for the type
of gas for which it has been regulated.