The returned error code is a decimal representation of an originally binary number.
In binary representation, the digits correspond to the following error messages:
Bit position Status message
0
error maximum heating temperature threshold exceeded
1
1 = error heating
2
1 = error temperature sensor interior
3
1 = error temperature sensor at the funnel
4
1 = error initialisation RTC
5
1 = error external temperature sensor
6
1 = poor quality of supply voltage