User Manual
Precipitation Sensor rain[e]H3 with Ethernet
Id-No. 00.15184.540 020
rain[e]H3
Precipitation Sensor
Manual
7.5
Available In- and Outputs
The
rain[e]H3
provides the following outputs:
Pulse Output:
• 1 galvanically isolated open-collector and
• 1 non-isolated open-collector
selectable as
• Pulse Output
◦
Resolution:
0.01...1 mm
◦
Closing time: 10...500 ms (duty cycle of 1:1)
• Status Output (heating ON/OFF; rain YES / NO)
Analogue Output:
• 0 / 4…20 mA
• 0...2.5 / 5 V
Serial output:
• SDI-12
• RS485 (Talker-, WL ASCII protocol)
• Ethernet 100 MBit
7.6
Factory Settings
The factory settings of the
rain[e]H3
according to the standard connecting diagram are:
•
Galvanically isolated output as pulse output
Resolution:
0.1 mm
Closing time: 300 ms
Duty cycle:
1:1
• Non-isolated output as state output
State “Heating ON / OFF“
• SDI-12 protocol activated (on SDI-12 Interface, 1200 Bd)
• Analogue output OFF
• Heating activated
7.7 Connections
Connection power supply / RS485
Via the A-coded 8-pole M12 plug the power supply and outputs are connected. For the connection several cables
with different lengths are available. These cables have a unidirectional M12 cable sleeve and only have to be
plugged on. The pin-assignment is shown in the wiring diagram.
Connection Ethernet interface
The Ethernet interface is connected by a D-coded M12 plug. For the connection several cables with different lengths
are available. These cables have a unidirectional M12 cable sleeve and only have to be plugged on. Alternatively
a D-coded cable sleeve that can be assembled is available. The pins of the Ethernet cable will be assigned by
insulation displacement technique. Thus, no special tools are needed.
7.8
TTerminal Assignment
All unused wires must be connected to unused pins or insulated to avoid malfunctions.