User Manual
Precipitation Sensor rain[e]H3 with Ethernet
Id-No. 00.15184.540 020
rain[e]H3
Precipitation Sensor
Manual
Level the device with the assistance of the spirit
level by tightening the hexagon head screws in the
base evenly.
• Reassembly
◦
Cautiously put the inner protection
cylinder back into place.
◦
Plug in the terminal plug of the heating.
◦
Put the casing onto the device,
embossings into notches.
◦
Press down on the housing and turn it
clockwise towards “close”.
◦
Fasten the knurled screw.
◦
Insert the enclosed dirt trap spiral into the
funnel
The measuring edge of the upper
part of the housing is quite sharp.
There is a risk of cuts. It is therefore
recommended that on the measuring
edge not be pressed on and/or that
gloves are worn!
• Inserting of the dirt trap spiral
Insert the enclosed dirt trap spiral in the fun-
nel. The spiral should be held in such a way
that a complete turn in the anti-clockwise
direction is possible. Push the dirt trap spiral
in circular motion from above into the funnel
opening.
• Removing the dirt trap spiral
Grab the dirt trap spiral in such a way that a
complete turn in the anti-clockwise direction
is possible and pull it in a circular motion
towards the funnel opening.
In order to protect the collecting vessel
the dirt trap spiral must be inserted into
the collecting funnel.
Einsetzen
Entfernen
Insert
Remove
10