User Manual
Precipitation Sensor rain[e]H3 with Ethernet
Id-No. 00.15184.540 020
rain[e]H3
Precipitation Sensor
Manual
10
In- and Outputs
10.1 SDI-12 Interface
Communication using the SDI-12 protocol via the SDI-12 interface is based on the ‘SDI-12 A Serial-Digital
Interface Standard for Microprocessor-Based Sensors, Version 1.3, 2012’. The
rain[e]H3
can be used in bus
mode parallel to other
rain[e]H3
sensors.
The following subset of SDI-12 commands are implemented in the
rain[e]H3
.
For further details to the SDI-12 protocol we recommend the afore mentioned standard document or the web
page www.SDI-12.org.
Implemented SDI-12 commands:
Command
Function
Answer of the sensor
a!
Acknowledge Active
a<CR><LF>
?!
Address Query Command
a<CR><LF>
a
I
!
Send Identification
allccccccccmmmmmmvvvxx...xx<CR><LF>
aAb!
Change Address
b<CR><LF>
aM!
Start Measurement
atttn<CR><LF>
aMC!
Start Measurement and Request CRC
atttn<CR><LF>
aC!
Start Concurrent Measurement
atttnn<CR><LF>
aCC!
Start Concurrent Measurement and Request
CRC checksum
atttnn<CR><LF>
aD0!
aD1!
Send Data (Puffer 0)
Send Data (Puffer 1)
a<values<CR><LF>
a<values><CRC><CR><LF>
resp. with CRC checksum
aM1!
Generate Variance
atttn<CR><LF>
aM2!
Generate Heating Data
atttn<CR><LF>
aM3!
Start Intensity Measurement Average Value,
Maximum and Minimum
atttn<CR><LF>
aMC1!
Generate Variance and Request CRC
atttn<CR><LF>
aMC2!
Generate Heating Data and Request CRC
atttn<CR><LF>
aMC3!
Start Intensity Measurement Average Value,
Maximum and Minimum and Request CRC
atttn<CR><LF>
aC1!
Generate Variance
atttnn<CR><LF>
aC2!
Generate Heating Data
atttnn<CR><LF>
aC3!
Start Intensity Measurement Average Value,
Maximum and Minimum
atttnn<CR><LF>
aCC1!
Generate Variance and Request CRC
atttnn<CR><LF>
aCC2!
Generate Heating Data and Request CRC
atttnn<CR><LF>
aCC3!
Start Intensity Measurement Average Value,
Maximum and Minimum and Request CRC
atttnn<CR><LF>
aV!
Start Verification
atttn<CR><LF>
a = address of the respective sensor; standard sensor address = 0
SDI-12 commands always start with the address of the appropriate sensor. Therefore all other sensors on the
same bus will ignore these commands. SDI-12 commands end with ‘
!
’. All answers from sensors start with its
address, too, but end with the ASCII characters ‘Carriage Return’
<CR>
and ‘Line Feed’
<LF>
.
27