50
If a room thermostat is to be installed we recommend our CLASS PIU’ timer-thermostat which, in addition to
guaranteeing comfort and precise temperature regulation, provides a wide range of heating programmes.
Alternatively there is the digital timer-programmer.
WARNING: The 230 V room thermostat must be connected to the earth terminal; alternatively, use the Class
II room thermostat.
CLASS PIU’ timer-thermostat (accessory)
-
checking for proper seal on gas/water fittings and pipes.
-
checking gas consumption at minimum and maximum power
-
checking position of ignition electrode
-
checking position of detection electrode
-
checking combustion and efficiency parameters
-
checking the no-gas safety device
-
checking combustion fumes outlet safety device (mod. M)
-
water system pressure
-
expansion tank efficiency
-
checking for proper operation of safety and adjustment thermostats
-
checking for proper circulation pump operation
-
checking that no gas whatsoever leaks from the system and no combustion gas leaks from the down-
draught diverter or the boiler-flue connection.
-
checking gas flow rate.
Do not clean
the unit and/or its component parts with easily inflammable substances (e.g. petrol, alcohol etc.)
Do not clean
panelling, painted and plastic parts with paint diluents. Clean the panelling with soapy water
only.