45
CONNECTION TO THE CHIMNEY - VERSION XILO T 24 M W TOP
The boiler is envisaged being
connected to a chimney
and/or a flue pipe; it can also discharge combustion
products
directly outside
.
The connection to the chimney or to the flue must be made with a
flue pipe
with the following specification:
●
of being sealed airtight, as with the connection to the chimney itself;
●
of being of suitable material;
●
of being connected within sight;
●
not having more than three directional changes, not being more than 3, and be made with internal
angles higher than 90
°
and utilizing bends;
●
of not having any intercepting devices;
●
of having the axis at the entrance of the terminal section perpendicular to the opposite internal wall of the
chimney;
●
of being firmly fixed and sealed at the entrance, without protruding beyond the inner walls of the chimney;
●
of receiving preferably one boiler only;
●
of observing the local regulations in force.
FLUE EXHAUST CONNECTION
Ø 132,5 mm
3%
1000 mm
min. 265 mm
H max. 2500 mm
4
1009DIS55
NO
YES
Flue pipe
or chimney
WARNING:
This unit is fitted with a Flue Control device to control flue draught. This device is tripped when
there is a risk of combustion fume backflow. This device must never be deactivated. If combustion
fumes re-enter the room they may cause chronic or acute intoxication and can be fatal. If the
Flue Control device is changed use only original spare parts. If the device trips repeatedly
check for proper fume outflow via the chimney flue and contact a Lamborghini Service Centre.