46
FUME EVACUATION/AIR INTAKE
1
Concentric flue pipe, from the roof C32
2
Concentric flue pipe, from the terrace C32
3
Double flue pipe from separate flues C42
4
Concentric flue pipe, connected to concentric flues C42
5
Concentric flue pipe, from an external wall C12
6
Double flue pipe from the terrace C52
7
Double flue pipe from single flue C82
8
Double flue pipe C62
CONNECTION TO THE CHIMNEY - VERSION XILO T 24 MS W TOP
The boiler is for combustion in a sealed chamber and does not require any special ventilation, it can also be
located in small rooms, lumber-rooms, laboratories. In addition, there are various possibilities for combustion
fume evacuation and external air intake. Basically the boiler is designed for two types of fume evacuation/air
intake:
●
fume evacuation/air intake concentric pipe system;
●
fume evacuation/air intake double pipe system;
In this way it is possible, by using suitable kits, to connect the boiler to concentric flues, ventilating flues,
separate flues, etc. Some possible solutions are indicated on page 46.
For positioning and for distances of draught terminals from windows, doors, etc. see
regulations in force
.
4
3
3
2
1
5
4
6
7
8
5
6