47
FLUE EXHAUST INSTALLATION
Attention: Use only air intake/ fume evacuation kits produced by Lamborghini Caloreclima.
CONCENTRIC FLUE PIPE
Fit the concentric elbow pipe positioning it on the desired direction and insert on it the sealing gasket. Then fit
the appropriate diaphragm (see table below).
Fit the air intake and flue exhaust pipes, observing the distances indicated on the installation scheme. The flue
pipe should slope slightly outward.
DOUBLE FLUE PIPE
Maximum length of CONCENTRIC FLUE PIPE 3 m
Maximum length of DOUBLE FLUE PIPE.
( Exhaust) 30 m
Installing an elbow to connect the boiler to the chimney will cause a
drop in pressure.
The values set out in the table below indicate the necessary
modifications to the length of the linear pipes.
100 Max. 3000
220
Ø100
105
440
770
100
Max. 3000
160
330
FLUE EXHAUST PIPE
Air
diaphragm
Ø100
1 m
0,6 m
TYPE OF
INSTALLATION
ELBOW FITTED
AT 90
°
ELBOW FITTED
AT 45
°
Concentric flue pipe
Separate intake/exhaust
0,5 m
0,3 m
** Air intake Ø 80
97
250
1009DIS1349
Air diaphragm
CONCENTRIC FLUE PIPE
Diaphragm
Ø 87 mm
DOUBLE FLUE PIPE
Max.
length 0,5
÷
1 m
over 1 m
max. 3 m
No diaphrag
(hole standard)
No diaphragm
(hole standard)
Summary of Contents for XILO T 24 M W TOP
Page 29: ...58...