background image

11

INSTRUCTION FOR THE USE

In case of breakdown and/or malfunctioning of the appliance, disconnect it avoiding any attempt of
repair or direct intervention.
Call exclusively professionally qualified personnel.

Any repair must be carried out by an after-sale service centre “LAMBORGHINI SERVICE” authorised by

the manufacturing firm, and using original replacements exclusively.

Non-observance of the above could compromise the guarantee and the safety of the appliance.

In order to guarantee the efficiency of the appliance and its proper operation it is indispensible to keep to

the manufacturerís directions, by ensuring the periodical servicing of the appliance is carried out by

professionally qualified personnel.

Check the hydraulic pressure of the installation on the hydrometer and that the indication, when the system

is cold, is within the limits set by the manufacturer: if one should find a drop in pressure request for an

inspection by qualified personnel.

After each reopening of the gas cock wait a few minutes before restarting the boiler

Do not leave the boiler switched on if it is not used for long time: in this case switch gas main supply,

electricity and water supply off by their own cocks and switches.

As soon as one decides not to use the appliance further, one should take care to render innocuous those

parts liable to be potential sources of danger.

As soon as one decides to disconnect the boiler definitively, one should ask qualified personnel to effect

the related works, then ensure that the main supplies have been disconnected.

For the power supply to the boiler the use of adaptors, multiple sockets or extensions is not permitted.The

use of a switch as indicated by the safety regulations in force must be provided.

The use of appliances which utilise electrical energy involve the observation of fundamental rules which

are:

a)

not to touch the appliance with parts of the body which are wet or when in bare feet;

b)

not to pull electrical wires;

c)

not to expose the appliance to the atmospheric agents;

d)

not to allow use of the appliance to children or the inexperienced.

In the case of structural work positioned near the flue pipe, turn off the boiler and at the end of the work

ensure that the efficiency of the flue exhaust is verified by qualified personnel.

On noticing the smell of gas do not touch any electric switch.Open all doors and windows. Shut off the gas

cocks and call qualified personnel.

Summary of Contents for XILO T 24 M W TOP

Page 1: ...TO MANUALE D USO AL SIG UTENTE PLEASE MAKE SURE THAT THE USE MANUAL IS HANDED OVER TO THE USER TENGAN LA AMABILIDAD DE ENTREGARLE AL USUARIO EL MANUAL DE USO FAVOR ENTREGAR O MANUAL DE USO AO SR UTENT...

Page 2: ...this manual at they give important safety instructions regarding installation and maintenance Keep this manual for future reference Installation must be carried out by qualified personnel who will be...

Page 3: ..._______________________________ 36 GAS NOZZLE CALIBRATION __________________________________________ 37 ELECTRICAL CONNECTIONS WIRING DIAGRAMS _______________________ 38 MALFUNCTIONS AND ADJUSTMENTS _...

Page 4: ...astic bags foam etc must not be left within reach of children as they are potential sources of danger This boiler is designed to heat water to a temperature below boiling atmospheric pressure It must...

Page 5: ...E CONTROL probe in the down draught diverter detects variations in temperature and shuts down the boiler Efficient operation of this safety system depends on observance of the following Do not deactiv...

Page 6: ...eading point 17 Expansion tank 18 Thermohydrometer 19 Malfunction warning light 20 ON OFF warning light 21 Lock out warning light 22 Hot water potentiometer if any 23 Function selector 24 Heating adju...

Page 7: ...I kg XILO T 24 MS W TOP Return kW kW kcal h Return Heater 3 4 3 4 3 4 3 4 3 4 Thermal capacity Min thermal capacity Connections Expansion tank Weight Input Output kcal h XILO T 24 M W TOP 3 4 3 4 3 4...

Page 8: ...s pressure mbar Gas type G20 20 mbar Natural Gas G30 28 30 mbar LPG G31 37 mbar LPG Burner jets mm 1 25 0 77 0 77 L C V kcal h 8 550 29 330 22 360 Delivery XILO T 24 MS XILO T 24 M m3 h 3 04 0 89 1 16...

Page 9: ...with safety REGULATIONS IN FORCE Grounde connections are compulsory Connect the boiler to an efficient grounding system To gain access to the electrical panel which houses the power supply terminal bl...

Page 10: ...TA Room thermostat if any TL Limit thermostat if any TIMER Boiler timer adjustment TST Safety thermostat VG Gas valve 1 Heating potentiometer 2 Selector Off Heater Heater Heating Reset Test 3 Hot wate...

Page 11: ...ing sensor SS Hot water sensor if any TA Room thermostat if any TL Limit thermostat if any TIMER Boiler timer adjustment TST Safety thermostat VG Gas valve VN Fan 1 Heating potentiometer 2 Selector Of...

Page 12: ...LA Timer G30 G31 LPG G20 Natural Gas post circ off heating post circ on 2 5 minutes JP2 JP1 Increase Increase Legend Off On Slow ignition adjustment Boiler timer adjustment R max Increase Max heating...

Page 13: ...ening for the connections Attach the boiler to the hooks through the holes at the back of the frame push it up against the wall Make the necessary water connections LEGEND G Gas 1 2 3 4 see tap suppli...

Page 14: ...tap 6 Safety valve 7 No water pressure switch 8 Circulator 9 Burner 10 Expansion tank 11 Fume pressure switch 12 Fan 13 Automatic air bleed valve 14 Total safety thermostat 15 Flue control 16 By pass...

Page 15: ...s wall of the approved type The flexible corrugated metal pipes must be installed in such a way that their length in a state of maximum extension is not greater than 2000 mm The boilers are calibrated...

Page 16: ...nal section perpendicular to the opposite internal wall of the chimney of being firmly fixed and sealed at the entrance without protruding beyond the inner walls of the chimney of receiving preferably...

Page 17: ...not require any special ventilation it can also be located in small rooms lumber rooms laboratories In addition there are various possibilities for combustion fume evacuation and external air intake...

Page 18: ...CENTRIC FLUE PIPE 3 m Maximum length of DOUBLE FLUE PIPE Intake Exhaust 30 m Installing an elbow to connect the boiler to the chimney will cause a drop in pressure The values set out in the table belo...

Page 19: ...fter its stop when reaching the temperature selected on the heating potentiometer bridge off 2 5 minutes MODULATION MAXIMUM PRESSURE ADJUSTMENT remove the protecting cover G place the function selecto...

Page 20: ...ency environmental hygiene and combustion may carry out work on the unit To ensure proper maintenance it is also required that such personnel be fully updated on the constructive and functional charac...

Page 21: ...on of ignition electrode checking position of detection electrode checking combustion and efficiency parameters checking the no gas safety device checking combustion fumes outlet safety device mod M w...

Page 22: ...r checking proper positioning of seal gaskets for model MS Then act as follows For transformation from G20 Natural Gas to G30 G31 LPG Insert the gas diaphram fig 2 Move jumper JP1 to ON position fig 3...

Page 23: ...e A Flue cross section or height with joint not suitable for the boiler B Excessive gas consumption combustion is imperfect C Flames tend to detach D Flame has yellow tips A Replace unsuitable compone...

Page 24: ...ge tap PAC S 80 450 mm PAC S 120 600 mm WATER CONNECTION MR Heating delivery RR Heating return MB Water heater delivery RB Water heater return ACS Hot water EAF Cold water inlet RIC Recirculation V No...

Page 25: ...as illustrated in the wiring diagram Disconnect the boiler power supply Undo the two grating screws fig 1 Undo the two casing fixing screws fig 2 Raise the casing and then pull it towards you fig 3 To...

Page 26: ...ANEL Turning dial A to the Heating Hot Water position as illustrated in the figure readies the boiler for operation with the heater Hot water temperature adjustment is effected by means of dial B on t...

Page 27: ...thermostat if any TIMER Boiler timer adjustment TST Safety thermostat VG Gas valve 1 Heating potentiometer 2 Selector Off Heater Heater Heating Reset Test 3 Hot water potentiometer if any ASSEMBLY DIA...

Page 28: ...sensor if any TA Room thermostat if any TL Limit thermostat if any TIMER Boiler timer adjustment TST Safety thermostat VG Gas valve VN Fan 1 Heating potentiometer 2 Selector Off Heater Heater Heating...

Page 29: ...58...

Page 30: ...rtuno per l evoluzione del prodotto The illustrations and data given are indicative and are not binding on the manufacturer LAMBORGHINI reserves the right to make those changes considered necessary fo...

Page 31: ...MODULATING USER MANUAL For the attention of the INSTALLATION TECHNICIAN make sure that this manual is handed over to the USER IT 2 CALDAIA MURALE A GAS TERMO ALTO RENDIMENTO MODULANTE MANUALE PER L UT...

Page 32: ...ULT FINDING CHART _________________________________________________15 Dear User you now own a product result of a thorough project and of advanced construction systems granting you the utmost reliabil...

Page 33: ...rts of the boiler which during the operation become overheated These parts can be dangerous for children or inexperienced persons Do not obstruct the inlet or dissipation screens Do not make the boile...

Page 34: ...me in this case switch gas main supply electricity and water supply off by their own cocks and switches As soon as one decides not to use the appliance further one should take care to render innocuous...

Page 35: ...t for other installations beyond not being ideal for such a use it could in short bring serious damage to the other appliances connected to it Ask qualified personnel LAMBORGHINI SERVICE to check a th...

Page 36: ...P 1 Lock out warning light 2 ON OFF warning light 3 Malfunction warning light 4 Heating adjustment potentiometer 5 Hot water adjustment potentiometer 6 Function selecto 7 Thermohydrometer CONTROL PANE...

Page 37: ...on corresponding to desired water temperature HEATING HEATER MODE IF ANY Turn the selector switch 6 to Heating Heater position Regulate the heating potentiometer 4 to a position that corresponds to de...

Page 38: ...ide boiler A Call technical service A Flue section or height with joint not suitable for the boiler B Excessive gas consumption combustion state is imperfect C Flames tend to move away or have yellow...

Page 39: ...l evoluzione del prodotto The illustrations and data given are indicative and are not binding on the manufacturer LAMBORGHINI reserves the right to make those changes considered necessary for the impr...

Reviews: