34
DESCRIPTION
These boilers are fully automatic and gas control is effected by an electronic control unit having the following
characteristics:
-
Continuous modulation mode on heating circuit;
-
Possibility to adjust the heating output;
-
Possibility to adjust the slow ignition;
-
Possibility of being combined with a water heater.
The models are equipped with:
-
No-water pressure switch;
-
Total safety thermostat;
-
High efficiency fume exchanger.
XILO T 24 M W TOP
Electronic ignition and ionization flame control.
Combustion and flue gas exhaust are of atmospheric type. It is equipped with flue gas exhaust control device
(FLUE CONTROL).
FLUE CONTROL THERMOSTAT
The XILO T 24 M boiler is fitted with the FLUE CONTROL thermostat for control of fume evacuation. An
increase in fume temperature in the down-draught diverter indicates an anomaly in fume evacuation. The
FLUE CONTROL probe in the down-draught diverter detects variations in temperature and shuts down the
boiler. Efficient operation of this safety system depends on observance of the following:
-
Do not deactivate the FLUE CONTROL thermostat.
-
Inspect the boiler and the flue immediately if the FLUE CONTROL device trips frequently.
-
If the FLUE CONTROL device is changed make sure you observe assembly and probe positioning instruc-
tions carefully and use
only original LAMBORGHINI spare parts
.
If there is a fume evacuation anomaly act quickly to prevent the formation of Carbon Monoxide, a poisonous
gas that causes intoxication and potentially fatal harm to both humans and animals.
XILO T 24 MS W TOP
Equipped with electronic control unit for automatic ignition and ionization electrode flame control.
To ensure safe operation, the electric fan is controlled by a pressure switch.
Flue gas exhaust can be made by means of the following:
-
a flue pipe concentric with the air intake pipe;
-
a double pipe, one for flue gas exhaust and the other for combustion air intake.
Summary of Contents for XILO T 24 M W TOP
Page 29: ...58...