46
DATA DISPLAY (MONITOR system)
Real-time data (not modifiable) regarding unit operation can be checked on the monitor. Press MODE twice (a
flashing indicator light appears to the right of the 1
st
figure). Press STEP to display all the available PHASES.
Notes
Phase n
°
Parameter
Sistema acqua calda sanitaria
Water delivery temp.
Return temp.
Hot water temp.
Outdoor temp. (*)
Fume temp.
Set or calculated delivery temp.
Parameters used by the installer
1
2
3
4
5
6
7,8
°
C
°
C
°
C
°
C
°
C
(*) Parameter displayed if connected to sensor (optional)
Unavailable
With OPTIONAL outdoor sensor
Access code input
To exit the DATA DISPLAY program press once.
59
MEDIDAS mm.
CARACTERÍSTICAS DEL CIRCULADOR
Caudal/altura manométrica disponible en la instalación
Ida calefacción Ø 3/4”
Retorno calefacción Ø 3/4”
Entrada agua fría sanitaria Ø 1/2”
Salida agua caliente sanitaria Ø 1/2”
Entrada gas Ø 3/4”
CARACTERÍSTICAS TÉCNICAS
Caldera versión: mod. C tipo C13-C33-C43-C53-C83
Temperatura máx. agua 90
°
C
Categoría: I 2H
Presión nominal gas: Gas natural 20 mbar
MODELO
Potencia térmica
Potencia térmica
mín
Producción agua caliente
Presión de
funcionamiento
Sanit.
Peso
Hogar
Útil
Hogar
Útil
Circuito
calefacción
máx.
Circuito
sanitario
máx.
Producción
∆
30
°
C
Toma de punta
en los primeros
10 minutos
kW kcal/h kW kcal/h
kcal/h
kcal/h
kW
kW
bar
bar
l/h
l
l
kg
25,53
30,1
21.957
25.886
24
27,87
20.640
23.968
10.922
12.040
10.320
11.558
12,7
14
12
13,44
680
760
145
160
10
8
90
90
3
3
6
6
3
3
81
82
BANOX 24 PLUS
MB W TOP
BANOX 28 PLUS
MB W TOP
Calefacción
l
8
8
Vasos de
expansión
Restablecimiento Capacidad
acumulador
min.
l
Summary of Contents for BANOX 24 PLUS MB W TOP U/IT
Page 2: ......