40
ASSEMBLY DIAGRAM
LEGEND
CiR
System circulating pump
PSG
Safety gas pressure switch
PA
Air pressure switch
PH
2
O
Water pressure switch
E.A.
Ignition electrode
E.R.
Detection electrode
TRA
Transformer
IG
Main switch
VG
Gas valve 1-2
M1
pa27 terminal board
VD
3-way valve
E/I
Summer/winter switch
TA
Room thermostat
TB
Water-heater thermostat
SE
External sensor
SR
Return sensor
SM
Delivery sensor
VN
Fan
X2
Amp. 13-pole connector
X3
Amp. 6-pole connector
X4
Amp. 2-pole connector
X7-X8
PC connector
3AT
Fuse 3A (electric fan)
2AF
Fuse 2A (24 V circuits)
2AF(F1)
Power supply fuse 230 V (2 A)
CL
230 V 50 Hz power lead
C
Connector Wieland
FA
Anti-interference filter
To connect the room thermostat TA, remove the bridge
1-2
from the
M1
terminal board.
65
Atención: Utilicen sólo y exclusivamente el kit de Aspiración/Expulsión humos Lamborghini Caloreclima.
INSTALACIÓN CONDUCTO EXPULSIÓN DE HUMOS
CONDUCTO EXPULSIÓN CONCÉNTRICO
Monten la curva concéntrica colocándola en la dirección deseada, introduzcan en la misma la junta estanca.
Monten los tubos de aspiración y de expulsión de los humos respetando las dimensiones indicadas en el
correspondiente esquema de instalación. Hay que mantener el conducto de expulsión de humos ligeramente
inclinado hacia el exterior.
CONDUCTO EXPULSIÓN HUMOS
RAMIFICADO
Longitud máx. CONDUCTO EXPULSIÓN CONCÉNTRICO 3 m.
Longitud máx. CONDUCTO EXPULSIÓN RAMIFICADO - BANOX 24
(Aspiración + Ida) 58 m.
Longitud máx. CONDUCTO EXPULSIÓN RAMIFICADO - BANOX 28
(Aspiración + Ida) 50 m.
La instalación de una curva en la unión de la caldera a la chimenea
crea una pérdida de presión.
Los valores de la tabla indican una reducción de tubería lineal.
INSTALACIÓN
TIPO
CONDUCTO EXPULSIÓN
CONCÉNTRICO
EXPULSIÓN/ASPIRACIÓN
SEPARADOS
COLOCACIÓN
CURVA A 90
°
1 mt.
0,6 mt.
COLOCACIÓN
CURVA A 45
°
0,5 mt.
0,3 mt.
Summary of Contents for BANOX 24 PLUS MB W TOP U/IT