35
DIMENSIONS mm
CIRCULATING PUMP FEATURES
Delivery/pressure available at the system
3/4” Ø heating delivery
3/4” Ø heating return
1/2” Ø cold water inlet
1/2” Ø hot water outlet
3/4” Ø gas inlet
TECHNICAL FEATURES
Boiler version: mod. C type C13-C33-C43-C53
-C83
Max. water temperature 90
°
C
Category: I 2H
Rated gas pressure: Natural gas 20 mbars
MODEL
Thermal capacity
Min. thermal
capacity
Hot water supply
Operating
pressure
Hot
water
Weight
Input
Output
Input
Output
Heating
circuit
max.
Hot water
circuit
max.
Water
supply
∆
30
°
C
Peak flow
over first
10 minutes
kW kcal/h kW kcal/h
kcal/h
kcal/h
kW
kW
bars bars
l/h
l
l
kg
25,53
30,1
21.957
25.886
24
27,87
20.640
23.968
10.922
12.040
10.320
11.558
12,7
14
12
13,44
680
760
145
160
10
8
90
90
3
3
6
6
3
3
81
82
BANOX 24 PLUS
MB W TOP
BANOX 28 PLUS
MB W TOP
Heating
l
8
8
Expansion
tanks
Reset
Water-
heater
capacity
min.
l
70
VISUALIZACIÓN DE LOS DATOS (sistema MONITOR)
Al visualizar los datos, se pueden controlar los valores instantáneos de funcionamiento del aparato (que no se
pueden modificar). Presionar dos veces el botón MODE (aparece un punto luminosos intermitente a la derecha
de la primera cifra). Presionar el botón STEP para visualizar todas las FASES disponibles.
Notas
N
o
fase
Parámetro
Sistema acqua calda sanitaria
Temperatura de ida
Temperatura de retorno
Temperatura circuito sanitario
Temperatura externa (*)
Temperatura humos
Temperatura de ida programada o calculada
Valores a disposición del instalador
1
2
3
4
5
6
7,8
Valor
°
C
Valor
°
C
Valor
°
C
Valor
°
C
Valor
°
C
(*) Visualización del valor si se ha conectado una sonda (opcional)
No disponible
Con sonda externa OPCIONAL
Introducción del código de acceso
Para abandonar el programa VISUALIZACIÓN DE LOS DATOS hay que presionar una vez