LM1510 Servo Drive Label Applicator
USER’S MANUAL
Page
64
Made in the U.S.A.
© 2019 LabelMill
11/01/2019 Model LM1510
REPLACING THE MAIN POWER FUSE
The circuitry is protected from a current overload by GMA 15A a fast blow fuse. Should the applicator fail to
operate, the condition of this fuse should be checked. If the fuse is open, the cause of the overload condition must
be determined and corrected prior to replacing the fuse. NEVER replace the fuse with one of a greater AMP
rating. The specified rating has been selected to prevent damage and/or injury.
ACTIONS TO REPLACE THE MAIN FUSE
1. Set the main power switch to the OFF position.
2. Disconnect the AC power cable from the rear of the console.
3. Locate the fuse holder/power cord assembly.
4. Gently press down the fuse holder cover while pulling away from the console.
5. Replace with the spare fuse provided in the holder.
5-4