![LabelMill LM1510 Operation Manual Download Page 49](http://html1.mh-extra.com/html/labelmill/lm1510/lm1510_operation-manual_3169597049.webp)
LM1510 Servo Drive Label Applicator
US
ER’S MANUAL
Page
49
Made in the U.S.A.
© 2019 LabelMill
11/01/2019 Model LM1510
QUICK START GENERAL SETUP
1. Inspect applicator system and verify all cables are installed properly.
2. Web system with labels.
3. Turn power switch on.
4.
Press “PROG”
5. Press UP arrow
6.
“ENTER” AUTO SETUP
7. System will feed out 2 to 10 labels to calibrate system.
8. If calibration fails, check label stock, web routing, cable connections and applicator condition.
9.
Attempt “AUTO SETUP” again
10. If AUTO SETUP fails again, manual set up will be required.
11. Once auto set up i
s complete, cycle system twice by pressing the “START key.
12. Observe label speed and change if required.
13. Manually move the label sensor so the label stops flush with the peeler plate tip.
14. System is now ready for set up of advanced features and options.
MANUAL SET UP
1. Inspect applicator system and verify all cables are installed properly.
2. Web system with labels.
3. Turn power switch on.
4.
Press “PROG”
5. Down arrow to
“DEFAULT SETTINGS” press ENTER
6. Press UP arrow to set defaults
7.
Perform “MANUAL-SET GAP”
8. Program in label length and Label gap length.
9.
Once manual set up is complete cycle system twice by pressing the “START key.
10. Observe label speed and change if required.
11. Manually move the label sensor so the label stops flush with the peeler plate tip.
12. System is now ready for set up of advanced features and options.
4-29