PASSWORD
The PASSWORD is used to lock the menus of the control. This option is used to prevent unauthorized access to
variable data. When shipped from the factory, the password is to 7074 and NO MENUS are locked. The
password cannot be changed.
AUTO SETUP
The AUTO SETUP function is used to determine the length of the label, gap length, recommended maximum
speed, and set label sensor values. (Note that when using a Clear label detector the sensor values are not
relevant) In this mode the applicator will feed 2
– 6 labels to auto set parameters explained above.
PRODUCT SENSOR
This is an external device that when “activated” starts the application cycle.
PROGRAMMABLE BLOCKS:
Product Delay
– delays the application of the label (x) seconds after the sensor has been activated **
Detector Lockout
– used with an external encoder to ignore trigger signals for programmed distance
Sensor Type
– used to designate the type of product sensor used,
Normally open
is the standard
Sensor Trigger
– designates whether the product sensor is activated at the leading or trailing edge of product
On Debounce
– programs how long (in seconds) a trigger signal must be received before activating applicator
Off Debounce
– used to ignore trigger signals (in seconds) after a cycle has completed
Multiple Feed
– how many labels are applied to one product with one signal (reset when signal is toggled)
Interval Delay
– amount of time in seconds between multiple fed labels
Note
: only active if quantity 2 or higher
** Note the product delay feature will not work when the
“Conveyor Lock”
feature is activated, use TRIGGER
DISTANCE and or with the
ENCODER turned on
the “INTERVAL DELAY” display will be replaced with DIST
0 to 2, DIST 0 to 3, DIST 0 to 4, etc. the interval between labels will use distance instead of time in this mode.
TAMP SETUP
This is used to adjust the different variables related to the tamp cycle.
PROGRAMMABLE BLOCKS:
Tamp Duration
– used to adjust the time that the tamp cylinder valve is actuated. (00.000 to 30.000)
Flag Duration
– used to adjust the time the flag jaws are held open after label application.(00.00 to 99.99)
Head Up Switch
– type:
normally open-
standard, normally closed, none
Head Up Debounce
– Debounce is used to allow time for the tamp cylinder to settle on return. (00.00 to 01.00)
Vacuum Release
– Used to release label when tamping on light products.
Vacuum Delay On
– Used to reduce label flutter when feeding large labels while tamping.
Tamp Sync Logic
– Used to interface a printer for loop print and apply.
LABEL SPEED
This is used to set the speed that the label is fed.
PROGRAMMABLE BLOCKS:
Inches per minute
– feeds the label at (x) inches per minute.
Acceleration (MS)
– sets the time that the motor takes to achieve full speed in (x) milliseconds.
Note: If acceleration is set too low (Quick) following errors may occur.