MANUAL-SET GAP
MANUAL-SET GAP is used to manually set the label sensor to the label stock that is webbed in the applicator.
This step is automatically taken care of in the AUTO SETUP mode covered in QUICK SETUP chapter. If the
values the applicator calculated are in question, the following will allow manual calibration of the label.
1. Go to MANUAL
–SET GAP press “enter”
2. Move label in label sensor gap until the LOWEST value is displayed
– press “enter” (center of label)
3. Move label in label sensor gap until the HIGHEST value is displayed
– press “enter” (gap between labels)
4. GAP THRESHOLD is now displayed. This is the difference between the highest value and the lowest value.
5. GAP THRESHOLD can be manually over ridden for difficult labels.
LABEL LENGTH and LABL GAP LENGTH
LABEL LENGTH is automatically calculated and entered when utilizing auto set up. If the length of the label is
known and does not match the displayed value, this can be manually entered.
LABL GAP LENGTH
– LABEL GAP LENGTH
LABEL GAP LENGTH is the space between two labels. LABEL GAP LENGTH is automatically calculated and
entered when utilizing auto set up. If the gap length of the label web is know and does not match the displayed
value this can be manually entered
. This distance is USUALLY .125”.