LAARS Heating Systems

Page 40

13.2 Parts List

ITEM DESCRIPTION

SIZE 125

PANEL ASSEMBLIES – 

See Figures 27-30

1

Panel, front, top, assy

12H3005

1A

Panel, top, upper

12H7001

1B

Screw, captive, .19 x .54 fast lead, phil pan hd F2028100

1C

Screw, #8-32 x 3/8", phil pan hd

F2027100

1D

Gasket, strip,  foam, adhesive, 3/8 x 1/8

S2113900

1E

Panel, front, top, subassy

12H3015

1F

Washer, retaining, .50 OD, nylon

F2028200

2

Panel, front, middle, assembly, LMH

12H3003

Panel, front, middle, assembly, LMC

12H3033

2A

Panel, front, middle, plastic

12H7002

2B

Gauge, press/temp, remote

A2117600

2C

Switch, Rocker, 120V, amber

E2335000

2D

Display module, electronic

RE2333500

2E

Hinge, front panel, middle

12H3008

2F

Circuit Breaker, 10 Amp, 120V

E2318900

2G

Circuit Breaker, 2A, 120V

E2335100

2H

Support, middle panel

12H3017

2I

Screw, #6 x 3/8" thd forming for plastic

1-418

2J

Screw, #8-32 x 3/8", phil pan hd

F2027100

2K

Rivet, pop, 3/16 diameter

F2015900

2L

Latch, magnet, .56 dia, 3.1 lbs

F2028300

2M

Harness, wire, power switch/circuit breaker

E2334501

2N

Harness, wire, d24V circuit breaker

E2334502

3

Panel, front, bottom, assembly

12H3004

3A

Control, programmed

12H7050

3B

Bracket, mounting,  control

12H7004

3C

Panel, front, bottom, plastic

12H7003

3D

Hinge, front panel, bottom

12H3007

3E

Rivet, pop, 3/16 diameter

3F

Screw, #8-32 x 3/8", phil pan hd

3G

Washer, retaining, .50 od, nylon

3H

Screw, captive, .19 x .54 fast lead, phil pan hd

4

Panel, left side

12H3019

SECTION 13.
Replacement Parts

Use only genuine LAARS replacement parts.

13.1 General Information

To order or purchase parts for the LAARS Mascot II, contact your nearest LAARS dealer or distributor. If
they cannot supply you with what you need, contact Customer Service (see back cover for address, telephone
and fax numbers).

ITEM DESCRIPTION

SIZE 125

5

Panel, right side

12H3018

BASE JACKET ASSEMBLY - 

see Figure 31

6

Base, jacket, assembly

12H3001

6A

Base, jacket

12H3011

6B

Screw, 8-32unc x 1.5l

F2001900

6C

Bracket, wall attach

12H3012

6D

Screw, hex head, 1/4-20 unc x .75" lg.

F2011600

6E

Nut, flange, serrated, hex head, 1/4"

10-103

6F

Bracket, hx, right side

12H3010

6G

Bracket, hx, left side

12H3016

6H

Screw, #8-18 x 1/2, phil pan hd

F2027000

6I

Switch, pressure, air/gas, inlet

E2334900

6J

Transformer,40Va, 115V/24V

R0021300

6K

Bracket, transformer

12H3009

6L

Rivet, pop, 3/16 diameter

F2015900

HEAT EXCHANGER CABINET - 

see Figure 32

7A

Grommet, pipe, wire, multi size, rubber

S2114000

7B

Heat exchanger

S2113800

7BB Gasket, vent adapter

12H5501

7C

Washer, clamping, hx bracket

12H3023

7D

Washer, M5, lock, internal tooth

F2023700

7E

Screw, M5-0.8 X 14mm, soc Hd

F2025300

7G

Gasket, blower fan

S2105400

7H

Screw, #8-18 x 1/2, phil pan hd

F2027000

7I

Vent, air, auto, 1/4" bspp

P2074500

7J

Pipe, air vent

12H4010

7K

Sensor, temperature, water, 1/4" npt

RE2320600

7L

Rivet, pop, 3/16 diameter

F2015900

7M

Terminal, 1/4" push-on, male, red

E0005501

7N

Heat exchanger

S2113800

7O

Blower, combustion air

RA2107500

7P

Washer, sealing, .410 OD

F2027700

7Q

Plate, venturi

12H5002

7R

Screw, m5 x 8, soc hd cap

F2029300

7S

O-ring, 2 1/8 id  x 3/32 thick

S2116000

7T

Adapter, vent, cpvc

12H5500

7U

Plug, hex, 1/8" npt

500-168

7V

Sensor, temperature, air, 1 /4" bsp, 1.85 l

RE2319700

7W Sensor, temperature, water, duplex

RE2319900

Summary of Contents for Mascot II

Page 1: ...monoxide gas in flue gases which could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instr...

Page 2: ...ating System Pump Capacity 17 SECTION 6 Water Connections 6 1 Central Heat System Piping 17 6 2 Cold Water Make Up 17 6 3 Freeze Protection 18 6 4 Suggested Piping Schematics 19 6 5 Recognized Chemica...

Page 3: ...Operating the Burner and Set Up 32 10 2 1 Burner Operation 32 10 2 2 Boiler Setup and Adjustment 33 10 3 Shutting Down Mascot II 33 10 4 To Restart Mascot II 33 SECTION 11 Maintenance 11 1 System Main...

Page 4: ...he PRV should be installed prior to filling the system Refer to Figures 1 and 2 for PRV locations IMPORTANT The inlet gas pressure to the appliance must not exceed 13 W C 3 2kPa All installations must...

Page 5: ...sponsible for shortages and damage to the shipment whether visible or concealed 1 5 Unpacking The Mascot II is shipped in a single crate with the following standard components packed with the applianc...

Page 6: ...LAARS Heating Systems Page 6 Figure 2 Location of Components...

Page 7: ...Water Heaters Page 7 Figure 3 Dimensional Drawing Cond Hydronic DHW 2nd Gas Hydronic DHW 2nd Outlet Return Inlet Return Supply Supply Outlet Supply 3 4 3 4 1 2 3 4 1 2 3 4 1 2 3 4 PVC copper NPT copp...

Page 8: ...ertified to ULC S636 Intake air pipe must be PVC or CPVC that complies with ANSI ASTM D1785 F441 ABS that complies with ANSI ASTM D1527 or galvanized material Installer must comply fully with manufact...

Page 9: ...ll bracket are purposely offset NOTE Mascot II models include 16 on center mounting holes on upper rear of boiler jacket These holes are not identified on the mounting template If mounting conditions...

Page 10: ...of the combustion air intake pipe Maximum linear pipe length allowed is shown in Table 2 Subtract 5 allowable linear ft 1 5m for every elbow used The connection for the intake air pipe is at the top...

Page 11: ...el or otherwise must be certified to this ULC standard Appropriate selection of vent material is very important for proper performance and safe operation of the Mascot II The flue temperature of the M...

Page 12: ...e a nuisance or hazard 3 Locate the vent terminal so that vent gases cannot be drawn into air conditioning system inlets 4 Locate the vent terminal so that vent gases cannot enter the building through...

Page 13: ...4 3 feet 91 cm J Clearance to nonmechanical air supply Direct vent only 12 30cm 80 285 36 91cm inlet to building or the combustion air inlet 399 850 Other than Direct vent 4 ft 1 2m below 36 inches 91...

Page 14: ...shall be the responsibility of the property owner to secure the services of qualified licensed professionals for installation of hard wired carbon monoxide detec tors a In the event that the side wal...

Page 15: ...um speed Do not operate a summer exhaust fan Close fireplace dampers 4 Place in operation the appliance being inspected Follow the lighting instructions Adjust thermostat so the appliance will operate...

Page 16: ...ing plate Mascot II will function properly without the use of high altitude modification at elevations up to 10 000 feet 3050 m 2 The maximum inlet gas pressure must not exceed 13 W C 3 2kPa The minim...

Page 17: ...toff valves where required by code Suggested piping diagrams are shown in Figures 12 through 19 These diagrams are meant only as a guide Components required by local codes must be properly installed M...

Page 18: ...a boiler is subjected to freezing conditions and the boiler is not able to fire and or the water is not able to circulate there is a risk of freezing in the boiler or in the pipes in the system When w...

Page 19: ...itable for use in the Mascot II Please refer to the manufacturers instructions for proper selection and application 1 Sentinel Performance Solutions Group 2 Hercules Chemical Company 3 Dow Chemical Co...

Page 20: ...3 42 38 15 33 31 28 Table 8 DHW and Pump Performance Data Caution Scalding Risk Laars recommends the use of a thermostatic mixing valve at domestic hot water outlet boiler location to reduce potential...

Page 21: ...Mascot II Boilers and Water Heaters Page 21 Figure 16 Hydronic Piping Multi boilers for large homes with long multiple baseboard zones Installer to provide DHW anti scald thermostatic mixing valve...

Page 22: ...LAARS Heating Systems Page 22 Figure 17 Hydronic Piping Multi boilers for large homes with long multiple radiant zones Installer to provide DHW anti scald thermostatic mixing valve...

Page 23: ...Mascot II Boilers and Water Heaters Page 23 Figure 18 Hydronic Piping Heating zones piped with zone pumps Installer to provide DHW anti scald thermostatic mixing valve...

Page 24: ...LAARS Heating Systems Page 24 Figure 19 Hydronic Piping Heating zones piped with zone valves Installer to provide DHW anti scald thermostatic mixing valve...

Page 25: ...he 24V field interlock as shown in the wiring diagram s 7 1 Main Power Plug power cord into a non switched 115V electrical outlet with 15A circuit protection FLA is 2A There is an internal 10A breaker...

Page 26: ...teps until all Modbus port 1 terminal A connections are wired d Repeat the above steps for Modbus port 1 terminal B and C connections to complete the wiring e Connect the drain wire from the twisted p...

Page 27: ...Mascot II Boilers and Water Heaters Page 27 Figure 22 Wiring Diagram...

Page 28: ...in Tables 9 11 Once in a particular menu structure navigation consists of pressing the next button to scroll from item to item and then pressing the up and down arrows to change values Once the value...

Page 29: ...to control temperature of an indirect tank 8 8 Lead Lag Cascading Lead Lag Cascading allows multiple boilers to be connected together and controlled from one common sensor input Up to 8 boilers can b...

Page 30: ...Reset Outdoor reset varies the control point setpoint based on the actual outdoor temperature The reset function works as shown in Figure 24 When the outdoor air temperature reaches the high outdoor t...

Page 31: ...then the boilers will simultaneously drop their firing rate If when reaching the point where both boilers drop toward their minimum firing rate 20 then the first slave will drop out Slave1 will remai...

Page 32: ...energize for pre purge then the ignition sequence starts After all safety devices are verified the gas valve opens If ignition doesn t occur turn off the Mascot II check that there is SECTION 10 Oper...

Page 33: ...can be forced to low fire to allow for easier setup Refer to Section 8 1 Table 11 for instructions on how to access the forced rate menu CO2 readings should be between the values shown in Table 13 If...

Page 34: ...LAARS Heating Systems Page 34 GAS TYPE HIGH FIRE CO2 LOW FIRE CO2 Natural 9 0 9 0 Propane 10 0 10 0 Table 13 CO2 Range Figure 25 Adjustment Screws and Settings for CO2...

Page 35: ...e Pump 11 2 1 Burner Check the burner for debris Remove the blower arm assembly to access the burner Remove the 4 bolts connecting the blower to the arm see Figure 32 Remove the 5 bolts which hold the...

Page 36: ...e soot deposits with a wet brush or fine water spray before servicing the heat exchanger 1 Shut off the 120 Volt power supply to the boiler 2 Turn off all manual gas valves connecting the boiler to th...

Page 37: ...um input CO2 Any high fire adjustment may affect low fire settings Screws for adjustment are shown in Figure 26 7 Reinstall front cover SECTION 12 Trouble Shooting 12 1 Sequence of Operation Mascot II...

Page 38: ...92 Outlet sensor fault 93 DHW sensor fault Faulty sensor or wiring Check wiring replace sensor condition can be 95 Stack sensor fault caused by short 96 OAT temperature sensor fault Faulty outdoor ai...

Page 39: ...values min 12 C 22 F to a difference greater than 22 F 12 C 255 CH setpoint minus ODR Increase Outdoor water min water temperature was temperature min and max too small min 12 C 22 F values to a diff...

Page 40: ...ral Information To order or purchase parts for the LAARS Mascot II contact your nearest LAARS dealer or distributor If they cannot supply you with what you need contact Customer Service see back cover...

Page 41: ...1 4 npt E2337500 8O Exchanger heat plate 8P Tie cable 14 3 4 long x 0 31 wide heat stabilized F2029100 8Q Flow switch water E2337400 8R Pipe tailpiece 1 npt M x 3 4 tube cu 12H4023 8S O ring 120 1 ID...

Page 42: ...LAARS Heating Systems Page 42 Figure 28 Panel Assembly Door Top...

Page 43: ...Mascot II Boilers and Water Heaters Page 43 Figure 29 Panel Assembly Door Middle...

Page 44: ...LAARS Heating Systems Page 44 Figure 30 Panel Assembly Door Bottom...

Page 45: ...Mascot II Boilers and Water Heaters Page 45 Figure 31 Base Jacket Assembly...

Page 46: ...LAARS Heating Systems Page 46 Figure 32 Heat Exchanger Cabinet Fan...

Page 47: ...Mascot II Boilers and Water Heaters Page 47 Figure 33 Heat Exchanger Burner Components...

Page 48: ...LAARS Heating Systems Page 48 Figure 34 Pump Assembly Components...

Page 49: ...Mascot II Boilers and Water Heaters Page 49 Figure 35 Plumbing Components...

Page 50: ...LAARS Heating Systems Page 50...

Page 51: ...Mascot II Boilers and Water Heaters Page 51...

Page 52: ...Fax 603 335 3355 Applications Engineering 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 0130 www Laars com Litho in U S A Laars Heating Systems 1111 Document 1230A Dime...