Page 1: ...INSTA 80 These instructions must be left with the user Installation Guide...

Page 2: ...Diagram 6 Plumbing Diagram 7 Flow Rate Graph Chart 8 Pack Contents Checklist 9 Specifications 9 Installation Requirements 10 Installation 10 Commissioning 12 Fault Diagnosis 13 Maintenance 14 Cleanin...

Page 3: ...been designed to provide hot water all year round Performance may vary depending on incoming ambient water temperatures Guarantee For domestic installations Watersave guarantee the INSTA 80 against an...

Page 4: ...provided from the consumer unit to the INSTA 80 7 Isolate the electrical and water supplies before commencing installation The electricity must be switched off at the consumer unit and the appropriat...

Page 5: ...the INSTA 80 by a person responsible for their safety 20 Children should be supervised to ensure that they do not play with the INSTA 80 21 Always switch off the INSTA 80 at the electrical isolating...

Page 6: ...6 Wiring Diagram...

Page 7: ...7 Plumbing Diagram...

Page 8: ...5 5 2 5 37 4 5 5 3 32 4 5 5 3 5 28 4 5 5 4 25 4 5 5 4 5 22 8 5 5 2 49 8 5 5 2 5 41 8 5 5 3 36 8 5 5 3 5 32 8 5 5 4 29 8 5 5 4 5 26 13 5 5 2 54 13 5 5 2 5 46 13 5 5 3 41 13 5 5 3 5 37 13 5 5 4 34 13 5...

Page 9: ...try Point Pre Wired Cable Size 2 5mm Water Inlet Connection 15mm Flexi Hose Isolation Valve Water Entry Point Bottom Water Exit Point Bottom Minimum Running Pressure 0 5 bar at 1l min Maximum Static P...

Page 10: ...mended extras such as Push Taps Sensor Taps and Showerheads Plumbing installation is as follows See Diagram Page 7 The cold mains water supply is connected to the water inlet at the bottom of the INST...

Page 11: ...0 to heat the water Electrical installation is as follows Note Ensure that your electricity has been isolated at the mcb first The INSTA 80 requires a mcb with a rating of 25 amps The INSTA 80 can be...

Page 12: ...the temperature of the incoming cold water Turn off the cold water at the tap Make sure the isolating valve from the old hot water supply system is turned off Make sure the flow rate does not exceed...

Page 13: ...down Contact Watersave Water temperature too high Power setting too high Water flow too high Adjust the power setting to be lower Increase the water flow Water temperature too low Power setting too l...

Page 14: ...14 Maintenance Cleaning The INSTA 80 should be cleaned using only soapy water and a non abrasive cloth sponge Spare Parts...

Page 15: ...ons in this manual If this does not resolve the issue contact our Customer Services Team who will offer you or your installer help and advice If you experience problems check in this manual to see if...