COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
FA2100CVR
Rev. 15 Page 139
Apr. 14/16
Testing & Fault Isolation
23–70–04
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
B.
READ
−
OUT CENTER/7 (ROC/7)
−
Sound Card Setup
(1)
Double
−
click the CVDR Test icon on the ROC to start the software. The applic-
ation will launch with the Channels control screen displayed, as illustrated in
Figure 136.
Figure 136. CATS, Channels Control Screen
(2)
In the Channels control screen, click OK. The Channels control screen will dis-
appear.
(3)
Click the Volume control icon (it is the icon that looks like a speaker). The
Volume Mixer
−
Speakers (SB Audigy) control displays, see Figure 137.