COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
FA2100CVR
Rev. 15 Page 71
Apr. 14/16
Description and Operation
23–70–04
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
D.
DataLink Memory Capacity
The CVR is currently configured with 32 Mbytes of dedicated DataLink recording
memory. This provides for a recording duration far in excess of the existing two hour
requirement.
E.
DataLink Retrieval
Recorded DataLink information is retrieved from the CVR in much the same way as
audio data. All, or a portion, of the DataLink recording can be downloaded from the
CVR using Ground Support Equipment supplied by L
−
3, Aviation Recorders. The
Portable Interface can be used to download the DataLink recording to a PCMCIA
memory card. The DataLink recording can also be downloaded using the CICC/2 or
CICC/3 interface cable connected to a PC. The downloaded DataLink file can then
be displayed using the Audio DataLink Playback software utility. can also output
the recorded DataLink stream as a Hex ASCII file or Binary ASCII file for more ex-
tended user processing and display.
The document reference is online, please check the correspondence between the online documentation and the printed version.