![background image](http://html1.mh-extra.com/html/l-b-white/ts350df/ts350df_owners-manual-and-instructions_3272872017.webp)
Premier Ductable Heaters
Owner’s Manual • Premier 350
17
Service Instructions
1. Close the fuel supply valve to the heater and
disconnect the electrical supply before servicing
unless necessary for your service procedure.
&OHDQWKHKHDWHU¶VRUL¿FHZLWKFRPSUHVVHGDLURU
DVRIWGU\UDJ'RQRWXVH¿OHVGULOOVEURDFKHV
HWFWRFOHDQWKHRUL¿FHKROH'RLQJVRZLOOHQODUJH
the hole, causing combustion or ignition problems.
5HSODFHWKHRUL¿FHLILWFDQQRWEHFOHDQHGSURSHUO\
3. The high limit switches, heat/vent switch and ther-
mostat can be tested by disconnecting the leads at
the component and jumpering the leads together.
-- Reconnect the electrical supply and open fuel
supply valves.
-- If the heater lights, the component is defective and
must be replaced.
-- Do not leave the jumper on or operate the heater if
the part is defective. Replace the part immediately.
-- An alternate method for checking the components
is to perform a continuity check..
4. The air proving switch must not be jumpered. If
jumpered, the ignition control will not allow heater
operation. Test the air proving switch for continuity.
If defective, replace the switch
WARNING
Burn Hazard
Ŷ+HDWHUVXUIDFHVDUHKRWIRUDSHULRGRIWLPHDIWHU
the heater has been shut down.
Ŷ$OORZWKHKHDWHUWRFRROEHIRUHSHUIRUPLQJ
service, maintenance, or cleaning.
Ŷ)DLOXUHWRIROORZWKLVZDUQLQJZLOOUHVXOWLQEXUQV
causing injury.
WARNING
Fire and Explosion Hazard
Ŷ'RQRWGLVDVVHPEOHRUDWWHPSWWRUHSDLUDQ\
heater components or gas train components
such as gas valves, or gas hoses.
Ŷ$OOFRPSRQHQWSDUWVPXVWEHUHSODFHGLIGHIHFWV
are found.
Ŷ)DLOXUHWRIROORZWKLVZDUQLQJZLOOUHVXOWLQ¿UHRU
explosions, causing property damage, injury, or
death.
5. Open the respective case panel for access to
burner or fan related components.
6. For reassembly, reverse the respective service
procedure. Ensure gas connections are tightened
securely.
7. After servicing, start the heater to ensure proper
operation and check for gas leaks.
8. If pulley or fan keys are lost during service, re-
placements are made by using 3/16 in. (4.7 mm.)
square x 1 in. (2.54 cm) bar stock. Otherwise,
order Part #22955.
Belt Replacement
1. Remove the belt guard from the heater.
See Fig. 14.
2. Rotate the fan pulley CW while carefully lifting the
belt so it clears the fan pulley groove. See Fig.15.
3. Check the fan and motor pulleys for dirt. Clean
the pulleys if needed.
4. When reinstalling the belt, ensure the arrows are
directed CCW. See Fig. 16.
FIG. 14
Belt guard