![L.B. White AR080 Owner'S Manual And Instructions Download Page 61](http://html1.mh-extra.com/html/l-b-white/ar080/ar080_owners-manual-and-instructions_664851061.webp)
Oval 80 and Sentinel Radiant Tube Brood Heaters
Owner’s Manual • Oval 80 and Sentinel
25
D. Completion
1. Close the fuel supply valve to the heater and
allow the heater to burn off any remaining fuel.
2. Disconnect the heater from its electrical supply.
3. Remove the gauges and associated hardware.
Install plugs in gas control valve and in connec-
tor. Tighten all securely. Close and latch panel.
Reconnect air inlet to burner box if necessary.
4. Reconnect hose and adapter to sediment trap.
tighten securely.
5. Open fuel supply valve and reconnect electrical
supply to heater. Start the heater and check for
gas leaks. Set thermostat to desired temperature.