![L.B. White AR080 Owner'S Manual And Instructions Download Page 44](http://html1.mh-extra.com/html/l-b-white/ar080/ar080_owners-manual-and-instructions_664851044.webp)
Oval 80 and Sentinel Radiant Tube Brood Heaters
www.lbwhite.com
Owner’s Manual • Oval 80 and Sentinel
8
10. Check for gas leaks and proper function upon
brood heater installation and before building
repopulation.
11. This brood heater should be inspected for proper
operation by a quali
fi
ed service person at least
annually.
12. Always turn off the gas supply to the brood
heater when not in use.
13. This brood heater is equipped with a three-wire
electrical system. There is a hot lead, neutral
lead, and ground lead. The brood heater may or
may not incorporate a plug on the power cord for
the brood heater and may or may not incorporate
a pin for the ground wire. In any case, the
brood heater must be properly connected into
a grounded electrical supply using the ground
lead in the power cord. Failure to use a properly
grounded receptacble can result in electrical
shock, personal injury, or death.
14. Direct ignition brood heaters will make up to
three trials for ignition. If ignition is not achieved,
the control system will lock out the gas control
valve. If gas is smelled after system lock out
has occurred, immediately close all fuel supply
valves. Do not relight until you are sure that all
gas that may have accumulated has cleared
away. In any event, do not relight for at least 5
minutes.
15. Use only approved gas hose or approved
fl
exible
connectors which are rated for use with propane
or natural gas.