![L.B. White AR080 Owner'S Manual And Instructions Download Page 40](http://html1.mh-extra.com/html/l-b-white/ar080/ar080_owners-manual-and-instructions_664851040.webp)
Oval 80 and Sentinel Radiant Tube Brood Heaters
www.lbwhite.com
Owner’s Manual • Oval 80 and Sentinel
4
Specifications
AR080
AT125
Available Tube Lengths (m)
6.1
12.2
Maximum Input per Hour kW
23.4
36.6
Fuel Consumption
per Hour (Max.)
LPG (kg)
1.7
2.63
NG (m³)
2.27
3.54
Gas supply pres-
sure acceptacle
for the purpose of
input adjustment
(kPa/mbar/In.W.C.)
MAX.
LPG
3.36 / 33.6 / 13.5
NG
MIN.
LPG
2.74 / 27.4 / 11.0
NG
1.74 / 17.4 / 7.0
Burner manifold pressure
(kPa/mbar/In.W.C.)
LPG
2.49 / 24.9 / 10.0
NG
1.0 / 10.0 / 4.0
Ventilation air
required to support
combustion (m³/
hour)
238
Motor
characteristics
30 Watts / 2500 RPM CW Rotation
Electrical supply
(Volts/Hz/Phase)
220-230 / 50 / 1
Amp draw
Starting
1.0
Continous
Operation
0.7
Minimum safe
distances of heater
from nearest com-
bustible materials
(m) See Fig. 1 on
page 5.
Top
0.3
Sides
0.76
1.83
Discharge End
1.83
Below radiant tubes
1.52
1.83
Temperature
sensor location
See Fig. 2 on page 5 of the owner’s manual