Lighting Instructions
Workman 100 Plus Natural Gas
1. Follow the instructions on the knob of the safety control
valve knob to light:
-- Turn the knob counter- clockwise (CCW) from OFF to
the PILOT position.
-- Fully depress the knob while repetitively pushing the
igniter’s button.
-- Keep the knob depressed in the PILOT position for
about 30 seconds to allow the thermocouple to warm up.
■
On new installations it may take a short time for gas to
purge out any air before the pilot lights and stays lit.
-- Release the knob on the safety control valve.
-- Turn the knob counterclockwise to ON. The main burner
will light.
FIG. 10
Shut-Down Instructions
A. To properly shut heater down after normal use, or
when further use is anticipated:
-- Turn the knob on the pilot safety control valve to the
PILOT position. The main burner will shut off but
the pilot light will remain lit.
B. To properly shut heater down for storage, or when
further use is not anticipated:
1. Close the fuel supply valve.
2. Allow the heater to burn off any fuel gas remaining
on the gas supply line.
3. Slightly depress the safety control valve’s knob and
turn the knob clockwise to OFF position.
4. Disconnect the heater from its gas supply.
IGNITER BUTTON
CONTROL
VALVE KNOB
Summary of Contents for 320
Page 32: ...Vertical Convection Heaters www lbwhite com Owner s Manual Workman Norseman 32...
Page 65: ...Calefactores de convecci n verticales www lbwhite com Manual del usuario Workman y Norseman 32...
Page 98: ...Fournaises verticales convection www lbwhite com Manuel du propri taire Workman et Norseman 32...