74
Ducting
Wall or floor registers, and return air grills MUST be kept clear of any
obstructions. Any such restrictions will prevent the furnace from full
operation. Closeable registers will reduce air flow. Never shut any register
off completely, possibly causing furnace to limit out and shut down.
Propane pressure, as defined in Chapter 4 - Systems, is extremely
important. A dial gauge, manometer, or U-tube is required to perform
tests and to make adjustments. Pressure must be set at 11 inches WC,
(water column) plus or minus 1/2 inch. Incorrect gas pressure can cause
any appliance to operate inconsistently and have poor combustion. Only
qualified technicians with proper equipment should make any mechanical
adjustments.
Voltage must be between 10.5-volts to 13.5-volts at the furnace during
operation. Below 10.5-volts the furnace will shut down. Both high and low
voltage places excessive wear on the motor and brushes.
Any mechanical adjustments, such as electrode adjustments or propane
adjustments must be performed by a qualified service technician.
Range and Oven Top Burner
Several types of cooking appliances are used in KZRV products. A drop-
in stove with 2 or 3 burners, a standard oven with 3 top burners, or an
oven with top burner piezo lighter. These appliances operate with
propane gas ONLY. NEVER use natural gas or butane.
Before attempting to light the stove, top burners or oven, BE SURE the
valve on the propane container is open.
This 3 burner range features blue LED lights on each burner knob. Fuse
for the lights is located behind the switch on converter and fuse panel.
Be sure all control knobs are turned “OFF” when you are not
cooking. Someone could be burned or a fire could start if a
burner is accidently left on and unattended, even if only
momentarily.
DO NOT operate this appliance unless the privacy curtain is
secure. FAILURE TO COMPLY COULD RESULT IN FIRE OR
SERIOUS INJURY.