2PR
1-4-34
(15) Fusing is loose.
(16) Colors are printed offset to each other.
Print example
Causes
Check procedures/corrective measures
Wrong types of paper.
Check if the paper meets specifications, replace paper.
Flawed heat roller or fuser belt.
Replace the fuser unit (See page 1-5-24).
Print example
Causes
Check procedures/corrective measures
Defective calibration.
Perform the color calibration (Refer to operation guide).
Slip the mirror position of laser scan-
ner unit.
Perform the color registration. When the problem is not
cleared, perform the manual color registration adjustment
(Refer to operation guide).