2PR
1-4-9
2102
Developing motor MCY error
The ready signal cannot be detected
within 5 seconds after the developing
motor MCY turns on.
Defective harness
between develop-
ing motor MCY and
engine PWB
(YC27), or
improper connec-
tor insertion.
Reinsert the connector. Also check for conti-
nuity within the connector harness. If none,
remedy or replace the harness.
Defective drive
transmission
system of the
developing motor
MCY.
Check if the gears rotate smoothly. If not,
grease the bushings and gears. Check for
broken gears and replace if any.
Defective develop-
ing motor MCY.
Replace the developing motor MCY.
Defective engine
PWB.
Replace the engine PWB (See page 1-5-
28).
2201
Drum motor K error
The ready signal cannot be detected
within 5 seconds after the drum motor K
turns on.
Defective harness
between drum
motor K and
engine PWB
(YC608), or
improper connec-
tor insertion.
Reinsert the connector. Also check for conti-
nuity within the connector harness. If none,
remedy or replace the harness.
Defective drive
transmission
system of the drum
motor K.
Check if the gears rotate smoothly. If not,
grease the bushings and gears. Check for
broken gears and replace if any.
Defective drum
motor K.
Replace the drum motor K.
Defective engine
PWB.
Replace the engine PWB (See page 1-5-
28).
2202
Drum motor C error
The ready signal cannot be detected
within 5 seconds after the drum motor C
turns on.
Defective harness
between drum
motor C and
engine PWB
(YC608), or
improper connec-
tor insertion.
Reinsert the connector. Also check for conti-
nuity within the connector harness. If none,
remedy or replace the harness.
Defective drive
transmission
system of the drum
motor C.
Check if the gears rotate smoothly. If not,
grease the bushings and gears. Check for
broken gears and replace if any.
Defective drum
motor C.
Replace the drum motor C.
Defective engine
PWB.
Replace the engine PWB (See page 1-5-
28).
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Summary of Contents for ECOSYS P7035cdn
Page 1: ...SERVICE MANUAL Published in May 2014 842PR111 2PRSM061 Rev 1 ECOSYS P7035cdn...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 14: ...2PR This page is intentionally left blank...
Page 20: ...2PR 1 1 6 This page is intentionally left blank...
Page 28: ...2PR 1 2 8 This page is intentionally left blank...
Page 48: ...2PR 1 3 20 This page is intentionally left blank...
Page 154: ...2PR 2 1 20 This page is intentionally left blank...
Page 177: ......
Page 178: ......