2MH/2MJ/2MK/2ML
1-6-1
1-6 Requirements on PWB Replacement
1-6-1 Upgrading the firmware
Follow the procedure below to upgrade the firmware of control PWB (main controller and engine) and scanner
PWB.
Preparation
Extract the file that has the download firmware and put them in the USB Memory.
Procedure
1. Turn ON the power switch and confirm
if the screen shows “Ready to print”
then, turn OFF the power switch.
2. Insert USB memory that has the firm-
ware in the USB memory slot.
3. Turn ON the power switch.
4. About 40 seconds later, “FW-Update”
will be displayed and blinking the mem-
ory LED (this shows to start the down-
load).
5. Display the software that now upgrad-
ing (5 minutes).
“FW- Update [CTRL]”
“[ENGN]”
“[SCAN]”
6. Display the completion of the upgrade
(Memory LED is ON condition).
7. Cut the power supply by pulling out the
power cable and remove the USB
memory.
* : After the print engine farm is down-
loaded, it is not possible to turn it off
with the power switch.
Figure 1-6-1
Check the result of the version up
1. Output the service status by the U000
and confirm the firmware version.
USB memory
USB memory slot
Summary of Contents for ECOSYS FS-1035MFP/DP
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 25: ...2MH 2MJ 2MK 2ML 1 1 11 This page is intentionally left blank ...
Page 97: ...2MH 2MJ 2MK 2ML 1 3 66 This page is intentionally left blank ...
Page 141: ...2MH 2MJ 2MK 2ML 1 4 44 This page is intentionally left blank ...
Page 223: ...2MH 2MJ 2MK 2ML 2 1 24 This page is intentionally left blank ...
Page 229: ...2MH 2MJ 2MK 2ML 2 2 6 This page is intentionally left blank ...
Page 266: ...INSTALLATION GUIDE INSTALLATION GUIDE FOR PAPER FEEDER ...
Page 267: ......
Page 268: ......