Page
100
IM Easyfire 10/2008
© KWB – Kraft und Wärme aus Biomasse GmbH
10 Fuel extractor, type S
10 Fuel extractor, type S
10.2
Installation instructions, FE type S
The conveyor worm system is a versatile modular system (MBDK0001) in section 17). Place the supplied insulating
elements under all support brackets. This measure acoustically decouples the FE. The fastening bolts are anchored
in the floor with plugs and enclosed on all sides by insulating elements.
The axis of the extractor worm is offset 80 mm to the middle of the conveyor trough!
Prior to installing the worm, mark the position of the support brackets on the storage room floor. Check the floor for
evenness or incline use shims to align the support points. Follow the set-up plan relative to install position in the
storage room.
To ensure accessibility for possible
repairs wall clearances of at least
10 cm on the penetration side, and
least 15 cm to the flange plate must
be maintained. The resulting dead space
should be covered.
To minimize projections on the adjacent
room side or to align the eject point,
the worm can be variably pushed into
the storage room, maintaining the wall
clearances specified above.
Ensure that you maintain the necessary
removal areas, e.g. for the gear motor.
(MBDK0001 in section 17)
Sloped floor connection – FE type S (GS)
10.3
Installing the pellet worm
Bring in the parts
1.) Bring the parts into the storage room
If space is at a premium in the storage room, or for a one-piece worm
conveyor, place the worms in the associated troughs before bringing
them into the room.
Bring the conveyor troughs and associated worms into the storage
room through the fire protection doors and put them on the floor in the
proper sequence (MBDK0001 in section 17).
Then guide the worms into the associated troughs.
MA-Easyfire 10.2008_EN.indd 100
MA-Easyfire 10.2008_EN.indd 100
30.03.2009 13:30:44 Uhr
30.03.2009 13:30:44 Uhr