Adjustments
99
After the test
When the test is finished, remove the bag or recipient and weigh it.
Enter the weighed value (8).
•
If the difference between the weighed value and the theoretical
value indicated is less than 3%, the following screen is
displayed:
•
If the difference between the weighed value and the theoretical
value indicated is more than 3%, we recommend that you redo
the test.
You are advised to repeat the test until the preceding message
no longer appears.
The distribution rotor speed is now calculated automatically. The
display returns to the main menu.
Hectare counter
•
Displays, in hectares (ha) the total surface and sown surface since
the start of work.
•
The calculation values are automatically adjusted after the
distribution test (refer to section Distribution Test page 97).
•
The counter starts as soon as the distribution rotor starts turning.
To reset the "Surface" tab to zero, press on the button XX for 5
seconds.
The "Total surface" tab cannot be reset to zero.
Input :
Calibr value
3.25 kg
8
Input :
Calibr value
3.25 kg
Main menu after
the distribution test
Main menu after
the distribution test if
you use a speed
sensor
km/h
10.0
SW %
kg/ha
25.0
5.3
km/h
10.0
20.0/
SW %
kg/ha
25.0
5.3
50/
3.93 ha
12.07 ha
Total area:
Area:
Summary of Contents for a-drill
Page 80: ...Seed drill adjustment 80 Sowing tables ...
Page 81: ...Seed drill adjustment 81 ...
Page 82: ...Seed drill adjustment 82 ...
Page 83: ...Seed drill adjustment 83 ...
Page 84: ...Seed drill adjustment 84 ...
Page 85: ...Seed drill adjustment 85 ...
Page 89: ...Filling the seedbox 89 Qualidisc and Qualidisc Farmer Unfold the machine Fill in the seedbox ...
Page 95: ...Adjustments 95 Main display Organisation of the menus ...