Adjustments
100
Calibration of travel speed
It is necessary to carry out a calibration as the box uses these values
as a base to do the calculations (display of speed, dosing, calculation
of surfaces, etc.)
Test distance
The test distance is 100 metres (
328’
)
Measure a distance of 100 metres (
328’
).
Mark the start and finish.
In the main menu of the box, choose the tab “Speed calibration?”.
Press on XX to select this tab.
Choose the tab "Calibration distance 100m?".
Press on XX.
Press on XX to start the test and begin to advance.
Having travelled 100 metres (328’), press on XX to stop the
calibration.
The following message is displayed when the calibration is
finished.
The number of radar impulsions on the ground during the 100
metres is displayed. Note this number, as it could be useful in case
of loss of the calibration values.
=> STOP
Drive 100m
=> START
Test Track
100m ?
Calibrate
Speed ?
Speed
calibrated !
Summary of Contents for a-drill
Page 80: ...Seed drill adjustment 80 Sowing tables ...
Page 81: ...Seed drill adjustment 81 ...
Page 82: ...Seed drill adjustment 82 ...
Page 83: ...Seed drill adjustment 83 ...
Page 84: ...Seed drill adjustment 84 ...
Page 85: ...Seed drill adjustment 85 ...
Page 89: ...Filling the seedbox 89 Qualidisc and Qualidisc Farmer Unfold the machine Fill in the seedbox ...
Page 95: ...Adjustments 95 Main display Organisation of the menus ...