2.7. Multiple System Interlock
Multiple laser projectors may be daisy chained and controlled by a single E-STOP Remote. Any event
which enables the Interlock on any laser projector in the daisy chain will trigger the safety Interlock for all
the systems. After the event has been corrected the START button on the E-STOP Remote must be
pressed by the operator to disable the Interlock. After an Emission Delay period the laser projectors will
be ready for use.
Kvant Lasers s.r.o.
Burstberry - 1
Page 12 of 32