V3.3 11.07.2007 KRC-AD-KRC2ed05-BA en
KR C2 edition05
2.6.3
CI3 Standard board
Description
This board is used as standard in the robot controller and has no node of its
own. It connects the nodes that are present in the ESC circuit and distributes
the signals to the individual interfaces. The "Local E-STOP" state is indicated
via a relay. The ESC circuit can be reset using the reset button.
Board
Own node
Description
CI3 Standard
(
>>>
No
Indicates the following states:
Local E-STOP
CI3 Extended
(
>>>
Yes
Indicates the following states:
Operating modes
Local E-STOP
Drives ON
CI3 Bus (
>>>
Bus board" page 29)
No
Connecting board between the
ESC circuit and the SafetyBUS
p from PILZ
CI3 Tech (
>>>
Tech board" page 31)
Yes
This board is required for the
following components:
KUKA.RoboTeam
KUKA.SafeRobot
SafetyBUS Gateway
Output to the top-mounted
cabinet (external axes)
Power supply to a 2nd RDC
via X19A
Indicates the following states:
Operating modes
Local E-STOP
Drives ON