![Kühtreiber MAKin 400 S Instructions For Use Manual Download Page 24](http://html1.mh-extra.com/html/kuhtreiber/makin-400-s/makin-400-s_instructions-for-use-manual_2009620024.webp)
24 | en
manual
N-coder ii
N-coder i
synergic
inductance setting
Mig/MAg
- Adjustment of welding voltage/voltage correction
press the n-coder i in turn to switch to this function.
Manual
- setting the welding voltage
Synergic
- correction of factory voltage value
manual
N-coder ii
N-coder i
synergic
voltage adjustment / voltage correction
Mig/MAg
- Setting arc length
the function allows setting the arc length for the pulse and douBle pulse
process. press the n-coder i in turn to switch to this function.
pulse
double pulse
N-coder ii
N-coder i
arc length
Mig/MAg
- Setting 2-STRoKe function
the function indicates how the welding process is activated. When using this
mode, it is necessary to press the control button during welding, which sends
a signal to activate the welding process. pressing the control button starts the
welding process and activates the sequence of functions. to activate, press
the control button one after the other.
pulse
double pulse
manual
N-coder ii
control button
2-stroke
synergic
Mig/MAg
- Setting 4-STRoKe function
the function indicates how the welding process is activated. When using this
mode, it is necessary to press and release the control button, which sends a
signal to activate the welding process. the pre-Gas function is then activated,
followed by soFt start and transition to welding power. to complete the
welding process, the control button must be pressed and released again to
terminate the welding process and start the post-Gas function. to activate,
press the control button one after the other.
pulse
double pulse
manual
N-coder ii
control button
4-stroke
synergic
Mig/MAg
- Setting the S4T function
the function allows setting of a multi-stage process (start power - welding
power - end power). to activate, press the control button one after the other.
use the FuNctioN button and turn the control dial n-coder i takes you to the
start / end power settings. the function value is corrected by means of the
control n-coder ii. By pressing and holding the control button, iNitial poWer
is activated → releasing the button activates WeldiNG poWer → pressing
and holding the control button activates eNd poWer → release the button
to complete the welding process.
Initial power
- adjustable between 1-200 % of welding power. allows setting
higher than welding power.
Welding power
- main welding power
End power
- adjustable from 1-200 % of welding power. it allows setting only
lower than welding power.