8. - Instructions for work
FC2860TLD-3160TLD-3560TLD
55
KN281CGB_L
Mower conditioner
8.2.2 Ground pressure
The ground pressure is adjusted independently
on each side of the mower unit.
To check the ground pressure:
- Check that the hitch pins are at the proper height
H = 650 mm (26’’).
- Raise the mowing unit:
• The force F must be of approximately 60 daN
(135 lbf) on each side.
The pressure must be adapted to the nature and
moisture degree of the ground.
To adjust the suspension
- Raise the mowing unit for easier ground
pressure adjustment.
- Adjust both sides to the same setting.
- Move the locking plate upwardly to release the
rotation of the adjustment screw.
F
H