FC244R / FC244R HD
118
11. - Troubleshooting guide
KN330CGB_A
Mower conditioner
- Activate the tractor’s dual-action distributor to
lower the mowing unit to the ground.
The pressure gauge must display a pressure of 85
(1233 psi).
If this is not the case:
- Open the valve using 18 box spanner supplied
with the machine.
- (a): Operate floatation single acting valve to
increase or reduce the pressure in the
circuit.
- (b): Adjust the hydraulic circuit to 85 bar (1233
psi).
- Shut-off valve using 18 box wrench supplied with
the machine.
- Activate the tractor double acting valve in the
headland turn position direction.
- Wait until the machine is steady.
- Activate the tractor’s dual-action distributor to
lower the mowing unit to the ground.
The gauge must indicate a steady pressure of 85
bar (1233 psi).
If this is not the case:
- Re-start the procedure from stage 2.