11. - Troubleshooting guide
FC244/D/-FF/D-FF
141
KN329CGB_A
Mower conditioner
- Activate the tractor’s dual-action distributor to
lower the mowing unit to the ground.
The manometer must display a pressure of 80 bar
(1160 psi).
If this is not the case:
- Open the valve using 18 box spanner supplied
with the machine.
- (a): Operate floatation single acting valve to
increase or reduce the pressure in the
circuit.
- (b): Adjust hydraulic circuit to 80 bar (1160 psi).
- Shut-off valve using 18 box wrench supplied with
the machine.
- Activate the tractor double acting valve in the
headland turn position direction.
- Wait until the machine is steady.
- Activate the tractor’s dual-action distributor to
lower the mowing unit to the ground.
The gauge must indicate a steady pressure of 80
bar (1160 psi).
If this is not the case:
- Re-start the procedure from stage 2.